Graco 220-569 Heat Pump User Manual


 
42 307-809
Technical
Data
3.5:1
Ratio Quiet Senator Pumps, Models 220–565 and 220–568
Maximum Working Pressure
2.45 MPa, 24.5 bar (350 psi)
.
.
Air
Operating Range
0.28–0.7 MPa, 2.8–7 bar (40–100 psi)
.
Air
Consumption
See Performance Chart
.
. . . . . . . . . . . . . . . .
Continuous Duty Delivery
65.8 liter/min (17.4 gpm)
.
. . . . . . . .
Pump
Cycles Per Liter (gallon)
0.91 (3.44)
.
. . . . . . . . . . . . . . .
Maximum
Recommended Pump Speed
60 cycles/min.
. . . .
Air
Inlet
3/4 npsm(f)
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid
Inlet
1–1/2” npt(f)
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid
Outlet
1” npt
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted Parts
Model 220–565
Carbon Steel, Stainless Steel,
.
. . . . . . . .
Ultra-High Molecular W
eight Polyethylene, Leather
, PTFE
r
Model
220–568
Chrome-Plated Stainless Steel,
.
. . . . . . .
Ultra-High
Molecular W
eight Polyethylene, Leather
, PTFE
r
0
50
100
150
200
250
300
350
036912151821
10 21 31 41 52 62
11 23 34 46 57 68
GPM
l/min
CPM
60
50
40
30
20
10
0
1.68
1.40
1.12
0.84
0.56
0.28
CFM
m
3
/min
PUMP OUTLET PRESSURE
AIR CONSUMPTION
79
72
A
B
C
A
B
C
PUMP DELIVERY (T
est Fluid: No. 10 Motor Oil)
1.4, 14
0.7, 7
PSI
1.05, 10.5
0.35, 3.5
1.7, 17
2.45, 24.5
MPa, BAR
2.1, 21
To
find Outlet Pressure
(MPa/bar/psi)
at a specific
delivery
(liter/min or gpm) and operating air pressure
(MPa/bar/psi):
1. Locate
desired delivery along bottom of chart.
2.
Read vertical line up to intersection with
selected fluid outlet pressure curve (black
curves). Curve slopes from left to right.
Follow left to scale and read outlet pressure.
T
o find Pump Air Consumption
(m
3
/min or
CFM/min) at a specific delivery (liter/min or gpm)
and operating air pressure (MPa/bar/psi):
1.
Locate desired delivery along bottom of chart.
2.
Read vertical line up to intersection with
selected air consumption curve (gray curves).
Curve slopes from right to left. Follow right to
scale and read air consumption.
A
0.7 MPa, 7 bar (100 psi) air pressure
B
0.49 MPa, 4.9 bar (70 psi) air pressure
C
0.28 MPa, 2.8 bar (40 psi) air pressure
2.5:1
Ratio Quiet Senator Pumps, Models 220–567 and 220–570
Maximum Working Pressure
1.7 MPa, 17 bar (250 psi)
.
. . . .
Air
Operating Range
0.28–0.7 MPa, 2.8–7 bar (40–100 psi)
.
Air
Consumption
See Performance Chart
.
. . . . . . . . . . . . . . . .
Continuous Duty Delivery
89.9 liter/min (24 gpm)
.
. . . . . . . . . .
Pump
Cycles Per Liter (gallon)
0.66 (2.5)
.
. . . . . . . . . . . . . . . .
Maximum
Recommended Pump Speed
60 cycles/min.
. . . .
Air
Inlet
3/4 npsm(f)
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid
Inlet
1–1/2” npt(f)
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid
Outlet
1” npt
.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wetted Parts
Model 220–567
Carbon Steel, Stainless Steel,
.
. . . . . . . .
Ultra-High Molecular W
eight Polyethylene, Leather
, PTFE
r
Model
220–570
Chrome-Plated Stainless Steel,
.
. . . . . . .
Ultra-High
Molecular W
eight Polyethylene, Leather
, PTFE
r
0
50
100
150
200
250
0 5 10 15 20 25 30 35
13 25 38 50 63 75 88
19 38 57 76 95 114 133
GPM
l/min
CPM
1.7,
17
1.4, 14
1.05, 10.5
0.7, 7
0.35, 3.5
40
30
20
10
0
1.12
0.84
0.56
0.28
CFM
m
3
/min
PSI
PUMP OUTLET PRESSURE
AIR CONSUMPTION
MPa, BAR
50
1.40
A
B
C
A
B
C
PUMP DELIVERY (T
est Fluid: No. 10 Motor Oil)
To
find Outlet Pressure
(MPa/bar/psi)
at a specific
delivery
(liter/min or gpm) and operating air pressure
(MPa/bar/psi):
1. Locate
desired delivery along bottom of chart.
2.
Read vertical line up to intersection with
selected fluid outlet pressure curve (black
curves). Curve slopes from left to right.
Follow left to scale and read outlet pressure.
T
o find Pump Air Consumption
(m
3
/min or
CFM/min) at a specific delivery (liter/min or gpm)
and operating air pressure (MPa/bar/psi):
1.
Locate desired delivery along bottom of chart.
2.
Read vertical line up to intersection with
selected air consumption curve (gray curves).
Curve slopes from right to left. Follow right to
scale and read air consumption.
A
0.7 MPa, 7 bar (100 psi) air pressure
B
0.49 MPa, 4.9 bar (70 psi) air pressure
C
0.28 MPa, 2.8 bar (40 psi) air pressure