COOLING PERFORMANCE DATA GPH1324H41**
MODEL: GPH1324H41**
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 5963677159636771596367715963 67 715963677159636771
MBh 24.3 24.9 26.6 28.4 23.8 24.3 26.0 27.7 23.2 23.7 25.3 27.1 22.6 23.1 24.7 26.4 21.5 22.0 23.5 25.1 19.9 20.4 21.8 23.3
S/T 1.00 0.94 0.76 0.57 1.00 1.00 0.79 0.59 1.00 1.00 0.81 0.61 1.00 1.00 0.84 0.63 1.00 1.00 0.87 0.65 1.00 1.00 0.88 0.65
Delta T23221915222319152222191521 22 19 162021191519191814
980 KW 1.73 1.77 1.82 1.88 1.86 1.90 1.96 2.03 1.98 2.02 2.08 2.15 2.08 2.12 2.19 2.26 2.17 2.21 2.28 2.36 2.24 2.29 2.36 2.44
AMPS 7.4 7.5 7.7 8.0 7.9 8.0 8.3 8.5 8.5 8.6 8.9 9.2 9.0 9.2 9.4 9.8 9.5 9.7 10.0 10.3 10.0 10.2 10.5 10.9
HI PR 246 265 280 292 277 298 314 328 315 339 357 373 358 386 407 425 403 434 458 478 445 479 506 528
LO PR 114 122 133 141 121 129 140 149 126 134 146 155 132 140 153 163 138 147 161 171 143 152 166 177
MBh 23.6 24.1 25.8 27.6 23.1 23.6 25.2 26.9 22.5 23.0 24.6 26.3 22.0 22.5
24.0
25.7 20.9 21.3 22.8 24.4 19.3 19.8 21.1 22.6
S/T 0.95 0.89 0.73 0.54 0.99 0.93 0.75 0.56 1.00 0.95 0.77 0.58 1.00 0.98
0.80
0.60 1.00 1.00 0.83 0.62 1.00 1.00 0.84 0.62
Delta T24232016242320162423201623 23
20
16 22 22 20 16 20 21 19 15
80 875 KW 1.72 1.76 1.81 1.87 1.85 1.89 1.95 2.01 1.96 2.00 2.07 2.14 2.06 2.11
2.18
2.25 2.15 2.19 2.27 2.34 2.22 2.27 2.34 2.42
AMPS 7.3 7.5 7.7 7.9 7.8 8.0 8.2 8.5 8.4 8.6 8.8 9.1 8.9 9.1
9.4
9.7 9.4 9.6 9.9 10.2 9.9 10.1 10.4 10.8
HI PR 244 263 277 289 274 295 311 325 311 335 354 369 355 382
403
420 399 429 453 473 441 474 501 523
LO PR 113 120 131 140 120 127 139 148 124 132 144 154 131 139
152
162 137 146 159 169 142 151 164 175
MBh 22.5 22.9 24.5 26.2 21.9 22.4 23.9 25.6 21.4 21.9 23.4 25.0 20.9 21.3 22.8 24.4 19.8 20.3 21.7 23.2 18.4 18.8 20.1 21.4
S/T 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.54 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.04 0.97 0.79 0.59 1.05 0.98 0.80 0.60
Delta T24232016252421162524211725 24 21 172524211623221915
770 KW 1.69 1.73 1.78 1.84 1.82 1.86 1.92 1.98 1.93 1.97 2.03 2.10 2.03 2.07 2.14 2.21 2.11 2.16 2.23 2.30 2.18 2.23 2.31 2.38
AMPS 7.2 7.3 7.5 7.8 7.7 7.8 8.1 8.3 8.3 8.4 8.7 9.0 8.8 8.9 9.2 9.5 9.3 9.5 9.7 10.1 9.7 10.0 10.3 10.6
HI PR 239 257 272 283 268 289 305 318 305 328 347 362 348 374 395 412 391 421 444 464 432 465 491 512
LO PR 111 118 129 137 117 125 136 145 122 130 141 151 128 136 149 158 134 143 156 166 139 148 161 172
MBh 24.8 25.2 26.4 28.2 24.2 24.7 25.8 27.6 23.6 24.1 25.2 26.9 23.0 23.5 24.6 26.2 21.9 22.3 23.4 24.9 20.3 20.7 21.6 23.1
S/T 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.97 0.79 1.00 1.00 1.00 0.81 1.00 1.00 1.00 0.84 1.00 1.00 1.00 0.85
Delta T23242320232323202223232022 22 23 202121222019192018
980 KW 1.75 1.78 1.84 1.90 1.88 1.92 1.98 2.04 1.99 2.04 2.10 2.17 2.10 2.14 2.21 2.28 2.18 2.23 2.30 2.38 2.26 2.31 2.38 2.46
AMPS 7.4 7.6 7.8 8.0 7.9 8.1 8.3 8.6 8.5 8.7 9.0 9.3 9.0 9.2 9.5 9.8 9.6 9.8 10.1 10.4 10.1 10.3 10.6 11.0
HI PR 249 268 283 295 279 301 317 331 318 342 361 377 362 389 411 429 407 438 463 482 450 484 511 533
LO PR 115 123 134 143 122 130 142 151 127 135 147 157 133 142 155 165 140 149 162 173 144 154 168 179
MBh 24.0 24.5 25.7 27.4 23.5 23.9 25.1 26.8 22.9 23.4 24.5 26.1 22.4 22.8 23.9 25.5 21.2 21.7 22.7 24.2 19.7 20.1 21.0 22.4
S/T 1.00 0.96 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.95 0.77 1.00 1.00 0.99 0.80 1.00 1.00 1.00 0.81
Delta T25252320252524212425242124 24 24 212223242021212219
85 875 KW 1.73 1.77 1.82 1.88 1.86 1.90 1.96 2.03 1.98 2.02 2.08 2.15 2.08 2.12 2.19 2.26 2.17 2.21 2.28 2.36 2.24 2.29 2.36 2.44
AMPS 7.4 7.5 7.7 8.0 7.9 8.0 8.3 8.5 8.5 8.6 8.9 9.2 9.0 9.2 9.4 9.8 9.5 9.7 10.0 10.3 10.0 10.2 10.5 10.9
HI PR 246 265 280 292 277 298 314 328 315 339 357 373 358 386 407 425 403 434 458 478 445 479 506 528
LO PR 114 122 133 141 121 129 140 149 126 134 146 155 132 140 153 163 138 147 161 171 143 152 166 177
MBh 22.8 23.3 24.4 26.0 22.3 22.7 23.8 25.4 21.8 22.2 23.3 24.8 21.2 21.7 22.7 24.2 20.2 20.6 21.6 23.0 18.7 19.1 20.0 21.3
S/T 0.96 0.92 0.83 0.68 0.99 0.96 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.96 0.78
Delta T26262421262625212626252125 26 25 212425242122232320
770 KW 1.71 1.74 1.80 1.85 1.83 1.87 1.93 1.99 1.95 1.99 2.05 2.12 2.05 2.09 2.16 2.23 2.13 2.18 2.25 2.32 2.20 2.25 2.32 2.40
AMPS 7.2 7.4 7.6 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.8 9.0 8.8 9.0 9.3 9.6 9.3 9.5 9.8 10.2 9.8 10.0 10.3 10.7
HI PR 242 260 275 286 271 292 308 321 308 332 350 365 351 378 399 416 395 425 449 468 436 470 496 517
LO PR 112 119 130 139 118 126 137 146 123 131 143 152 129 137 150 160 135 144 157 168 140 149 163 173
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is AHRI Rating Conditions KW = Total system power
High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors)