Goodmans GPH 13 H Heat Pump User Manual


 
13
COOLING PERFORMANCE DATA GPH1324H41**
MODEL: GPH1324H41**
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 12±3 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 8±3 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 59636771596367715963677159 63 67 715963677159636771
MBh 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.9 22.7 24.8 - 20.8 21.5 23.6 - 19.3 20.0 21.9 -
S/T 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.85 0.71 0.49 - 0.88 0.73 0.51 - 0.91 0.76 0.53 - 0.92 0.77 0.53 -
Delta T 18 15 12 - 18 15 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
980 KW 1.71 1.74 1.80 - 1.83 1.87 1.93 - 1.95 1.99 2.05 - 2.05 2.09 2.16 - 2.13 2.18 2.25 - 2.20 2.25 2.32 -
AMPS 7.2 7.4 7.6 - 7.7 7.9 8.1 - 8.3 8.5 8.8 - 8.8 9.0 9.3 - 9.3 9.5 9.8 - 9.8 10.0 10.3 -
HI PR 242 260 275 - 271 292 308 - 308 332 350 - 351 378 399 - 395 425 449 - 436 470 496 -
LO PR 112 119 130 - 118 126 137 - 123 131 143 - 129 137 150 - 135 144 157 - 140 149 163 -
MBh 22.8 23.7 25.9 - 22.3 23.1 25.3 - 21.8 22.6 24.7 - 21.2 22.0 24.1 - 20.2 20.9 22.9 - 18.7 19.4 21.2 -
S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.87 0.73 0.50 - 0.88 0.73 0.51 -
Delta T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
70 875 KW 1.69 1.73 1.78 - 1.82 1.86 1.92 - 1.93 1.97 2.03 - 2.03 2.07 2.14 - 2.11 2.16 2.23 - 2.18 2.23 2.31 -
AMPS 7.2 7.3 7.5 - 7.7 7.8 8.1 - 8.3 8.4 8.7 - 8.8 8.9 9.2 - 9.3 9.5 9.7 - 9.7 10.0 10.3 -
HI PR 239 257 272 - 268 289 305 - 305 328 347 - 348 374 395 - 391 421 444 - 432 465 491 -
LO PR 111 118 129 - 117 125 136 - 122 130 141 - 128 136 149 - 134 143 156 - 139 148 161 -
MBh 21.7 22.5 24.6 - 21.2 22.0 24.1 - 20.7 21.4 23.5 - 20.2 20.9 22.9 - 19.2 19.9 21.8 - 17.8 18.4 20.2 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.70 0.48 - 0.84 0.70 0.49 -
Delta T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 15 12 -
770 KW 1.67 1.70 1.75 - 1.79 1.83 1.89 - 1.90 1.94 2.00 - 2.00 2.04 2.10 - 2.08 2.12 2.19 - 2.15 2.20 2.27 -
AMPS 7.1 7.2 7.4 - 7.6 7.7 7.9 - 8.1 8.3 8.5 - 8.6 8.8 9.1 - 9.1 9.3 9.6 - 9.6 9.8 10.1 -
HI PR 234 252 266 - 263 283 299 - 299 322 340 - 341 367 387 - 383 412 436 - 423 456 481 -
LO PR 109 116 126 - 115 122 133 - 119 127 139 - 125 133 146 - 131 140 153 - 136 145 158 -
MBh 23.9 24.6 26.7 28.6 23.4 24.1 26.0 27.9 22.8 23.5 25.4 27.3 22.2
22.9
24.8 26.6 21.1 21.8 23.6 25.3 19.6 20.2 21.8 23.4
S/T 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 1.00
0.89
0.68 0.44 1.00 0.93 0.70 0.45 1.00 0.94 0.71 0.46
Delta T20191511211916112119161121
19
16 11 20 19 16 11 18 18 14 10
980 KW 1.72 1.76 1.81 1.87 1.85 1.89 1.95 2.01 1.96 2.00 2.07 2.13 2.06
2.11
2.17 2.25 2.15 2.19 2.27 2.34 2.22 2.27 2.34 2.42
AMPS 7.3 7.5 7.7 7.9 7.8 8.0 8.2 8.5 8.4 8.6 8.8 9.1 8.9
9.1
9.4 9.7 9.4 9.6 9.9 10.2 9.9 10.1 10.4 10.8
HI PR 244 263 277 289 274 295 311 325 311 335 354 369 355
382
403 420 399 429 453 473 441 474 501 523
LO PR 113 120 131 140 120 127 139 148 124 132 144 154 131
139
152 161 137 146 159 169 142 151 164 175
MBh 23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1 22.8 24.7 26.5 21.6
22.2
24.1 25.8 20.5 21.1 22.9 24.5 19.0 19.6 21.2 22.7
S/T 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.92 0.83 0.63 0.40 0.95
0.85
0.65 0.42 0.99 0.88 0.67 0.43 1.00 0.89 0.68 0.43
Delta T21201611212016112120161122
20
16 11 21 20 16 11 20 18 15 10
75 875 KW 1.71 1.74 1.80 1.85 1.83 1.87 1.93 1.99 1.95 1.99 2.05 2.12 2.05
2.09
2.16 2.23 2.13 2.18 2.25 2.32 2.20 2.25 2.32 2.40
AMPS 7.2 7.4 7.6 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.8 9.0 8.8
9.0
9.3 9.6 9.3 9.5 9.8 10.2 9.8 10.0 10.3 10.7
HI PR 242 260 275 286 271 292 308 321 308 332 350 365 351
378
399 416 395 425 449 468 437 470 496 517
LO PR 112 119 130 139 118 126 138 146 123 131 143 152 129
138
150 160 135 144 157 168 140 149 163 173
MBh 22.1 22.7 24.6 26.4 21.5 22.2 24.0 25.8 21.0 21.7 23.4 25.2 20.5
21.1
22.9 24.5 19.5 20.1 21.7 23.3 18.1 18.6 20.1 21.6
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.38 0.88 0.79 0.60 0.39 0.91
0.82
0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.85 0.65 0.42
Delta T22201711222017122220171222
21
17 12 22 20 17 11 21 19 16 11
770 KW 1.68 1.72 1.77 1.82 1.81 1.84 1.90 1.96 1.92 1.96 2.02 2.08 2.01
2.06
2.12 2.19 2.10 2.14 2.21 2.28 2.17 2.21 2.29 2.36
AMPS 7.1 7.3 7.5 7.7 7.6 7.8 8.0 8.3 8.2 8.4 8.6 8.9 8.7
8.9
9.1 9.4 9.2 9.4 9.7 10.0 9.7 9.9 10.2 10.5
HI PR 237 255 269 281 266 286 302 315 302 325 343 358 344
370
391 408 387 417 440 459 428 460 486 507
LO PR 110 117 128 136 116 123 135 144 121 128 140 149 127
135
147 157 133 141 154 164 137 146 159 170
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions