Goodman Mfg TSTATG2111 Thermostat User Manual


 
Page 11.3
11
Adjusting the Cycles Per Hour
(d1, d, 2 - 6)
The Cycles Per Hour setting may limit the number of times per hour
your HVAC unit may energize. For example, at a setting of 6 cycles
per hour the HVAC unit will only be allowed to energize once every 10
minutes. The Cycles Per Hour limit may be overridden and reset by
pressing the UP or DOWN buttons on the thermostat.
Setup
Select the cycles per
hour limit.
d=cycles per hour
limit defeated.
d1=d + defeat 5 min.
compressor lockout.
Note: Press the MODE
button momentarily
to move through the
setup screens. Press
and hold the MODE
button to move back-
wards through the
setup screens.
6
14
CY
Air Conditionin
g
& Heatin
g
Press the SETUP button to leave the Setup screens. If no buttons are
pressed, the display will leave the setup screens after 30 seconds.
Press the MODE button repeatedly
until this setup screen appears.
Press
MODE
Press SETUP button to
enter Setup screens.