SS-DSZC18 www.goodmanmfg.com 21
expanded Heating data (Cont.)


65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 71.6 67.8 63.8 59.7 57.0 55.2 51.3 47.3 46.7 43.1 39.7 37.5 36.1 32.4 28.7 25.0 21.4 17.5
∆T 37.9 35.9 33.8 31.6 30.2 29.2 27.1 25.0 24.7 22.8 21.0 19.8 19.1 17.1 15.2 13.2 11.3 9.3
kW 4.94 4.84 4.73 4.63 4.6 4.52 4.42 4.32 4.28 4.17 4.07 4.00 3.96 3.85 3.75 3.65 3.54 3.44
Amps 24.5 22.1 20.2 18.6 17.6 17.1 15.7 14.5 13.6 12.6 11.7 11.2 10.9 10.0 8.8 7.9 6.7 5.3
COP 4.24 4.10 3.95 3.77 3.65 3.57 3.40 3.21 3.19 3.02 2.86 2.74 2.66 2.46 2.24 2.01 1.77 1.49
EER 14.5 14.0 13.5 12.9 12.5 12.2 11.6 11.0 10.9 10.3 9.8 9.4 9.1 8.4 7.7 6.9 6.0 5.1
HI PR 421 403 388 371 362 355 342 328 314 300 288 281 276 265 255 245 236 228
LO PR 127 118 111 102 96 92 85 76 68 61 54 50 48 41 35 30 26 20


65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 52.0 49.2 46.3 43.3 41.4 40.1 37.2 34.3 32.6 30.1 27.7 26.1 25.2 22.6 20.0 17.5 14.9 12.2
∆T 40.1 38.0 35.7 33.4 31.9 30.9 28.7 26.5 25.1 23.2 21.4 20.2 19.4 17.4 15.5 13.5 11.5 9.4
kW 3.66 3.58 3.50 3.42 3.4 3.34 3.26 3.18 3.23 3.15 3.06 3.01 2.98 2.90 2.81 2.73 2.65 2.57
Amps 17.5 16.2 15.1 14.2 13.6 13.4 12.6 11.9 11.3 10.8 10.3 10.0 9.8 9.3 8.6 8.1 7.4 6.6
COP 4.16 4.02 3.87 3.71 3.59 3.51 3.34 3.16 2.95 2.80 2.64 2.54 2.47 2.28 2.08 1.87 1.65 1.39
EER 14.2 13.7 13.2 12.7 12.3 12.0 11.4 10.8 10.1 9.6 9.0 8.7 8.4 7.8 7.1 6.4 5.6 4.8
HI PR 421 403 388 371 362 355 341 328 314 300 288 281 276 265 255 245 236 228
LO PR 138 128 120 110 104 100 92 82 74 66 58 54 52 44 38 32 28 22


65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 71.0 67.2 63.3 59.2 56.5 54.7 50.9 46.9 43.6 40.3 37.1 35.0 33.7 30.2 26.8 23.4 20.0 16.3
T/R 36.5 34.6 32.6 30.4 29.1 28.2 26.2 24.1 22.4 20.7 19.1 18.0 17.3 15.6 13.8 12.0
10.3 8.4
kW 4.57 4.48 4.39 4.30 4.2 4.21 4.12 4.03 4.52 4.41 4.31 4.24 4.20 4.09 3.99 3.88 3.77 3.67
Amps 21.4 19.8 18.5 17.3 16.7 16.4 15.4 14.6 14.0 13.3 12.6 12.3 12.2 11.5 10.7 10.1 9.3 8.3
COP 4.55 4.39 4.22 4.03 3.90 3.81 3.61 3.41 2.82 2.67 2.52 2.41 2.35 2.16 1.97 1.76 1.55 1.30
EER 15.5 15.0 14.4 13.8 13.3 13.0 12.3 11.6 9.6 9.1 8.6 8.2 8.0 7.4 6.7 6.0 5.3 4.5
HI PR 396 379 365 349 340 334 321 308 295 282 271 264 259 250 240 230 222 214
LO PR 132 123 115 106 100 96 88 79 71 63 56 52 50 42 36 31 27 21


65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10
MBh 49.8 47.1 44.4 41.5 39.6 38.4 35.6 32.9 29.8 27.5 25.3 23.9 23.0 20.7 18.3 16.0 13.6 11.2
T/R 38.4 36.4 34.2 32.0 30.6 29.6 27.5 25.4 23.0 21.2 19.5 18.5 17.8 15.9 14.1 12.3 10.5 8.6
kW 3.41 3.33 3.26 3.19 3.1 3.12 3.05 2.97 3.37 3.28 3.20 3.15 3.11 3.03 2.94 2.86 2.77 2.69
Amps 16.8 15.6 14.6 13.7 13.2 12.9 12.2 11.6 11.1 10.6 10.1 9.8 9.7 9.2 8.6 8.0 7.4 6.7
COP 4.28 4.14 3.98 3.81 3.68 3.60 3.42 3.24 2.59 2.45 2.32 2.22 2.17 2.00 1.82 1.64 1.44 1.22
EER 14.6 14.1 13.6 13.0 12.6 12.3 11.7 11.1 8.8 8.4 7.9 7.6 7.4 6.8 6.2 5.6 4.9 4.2
HI PR 401 384 370 353 345 339 325 312 299 286 274 268 263 253 243 233 225 217
LO PR 143 132 124 114 107 103 95 85 76 68 60 56 54 45 39 33 29 23
High pressure is measured at the liquid service valve ( the smaller valve). Amps = Outdoor unit amps (comp.+fan)
Low pressure is measured at the gauge port connecon. kW = Total system power
Calculaons are based on nominal CFM and 70 °F indoor dry bulb.