prodUCT speCifiCaTions
prodUCT speCifiCaTions
8 www.goodmanmfg.com SS-CPG180-240
expanded Cooling daTa 15 Tons

65 75 85 95 105 115

  59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
70
6075
MBh 176.4 182.8 200.3 - 172.3 178.6 195.6 - 168.2 174.3 191.0 - 164.1 170.1 186.3 - 155.9 161.6 177.0 - 144.4 149.7 164.0 -
S/T 0.71 0.59 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 15 12 -
HI PR 234 252 266 - 262 282 298 - 298 321 339 - 340 366 386 - 382 411 434 - 422 454 480 -
LO PR 102 109 119 - 108 115 126 - 112 120 131 - 118 126 137 - 124 132 144 - 128 136 149 -
5400
MBh 171.2 177.5 194.5 - 167.3 173.4 189.9 - 163.3 169.2 185.4 - 159.3 165.1 180.9 - 151.3 156.9 171.9 - 140.2 145.3 159.2 -
S/T 0.68 0.57 0.39 - 0.70 0.59 0.41 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.65 0.45 - 0.78 0.65 0.45 -
∆T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 19 16 12 -
HI PR 231 249 263 - 260 279 295 - 295 318 336 - 336 362 382 - 378 407 430 - 418 450 475 -
LO PR 101 108 118 - 107 114 124 - 111 118 129 - 117 124 136 - 122 130 142 - 127 135 147 -
4320
MBh 158.1 163.8 179.5 - 154.4 160.0 175.3 - 150.7 156.2 171.1 - 147.0 152.4 167.0 - 139.7 144.8 158.6 - 129.4 134.1 146.9 -
S/T 0.65 0.55 0.38 - 0.68 0.57 0.39 - 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.75 0.63 0.43 -
∆T 22 19 14 - 22 19 15 - 22 19 15 - 22 19 15 - 22 19 15 - 21 18 14 -
HI PR 224 242 255 - 252 271 286 - 286 308 326 - 326 351 371 - 367 395 417 - 406 436 461 -
LO PR 98 105 114 - 104 110 121 - 108 115 125
- 113 121 132 - 119 126 138 - 123 131 143 -
75
6075
MBh 179.4 184.7 199.9 214.5 175.2 180.4 195.3 209.6 171.0 176.1 190.6 204.6 166.9 171.8 186.0 199.6 158.5 163.2 176.7 189.6 146.8 151.2 163.6 175.6
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
∆T 22 20 17 11 22 20 17 12 22 20 17 12 22 21 17 12 22 20 17 12 21 19 16 11
HI PR 236 254 268 280 265 285 301 314 301 324 342 357 343 369 390 407 386 415 439 458 427 459 485 506
LO PR 103 110 120 128 109 116 127 135 114 121 132 140 119 127 138 147 125 133 145 155 129 138 150 160
5400
MBh 174.2 179.3 194.1 208.3 170.1 175.1 189.6 203.5 166.1 171.0 185.1 198.6 162.0 166.8 180.5 193.8 153.9 158.5 171.5 184.1 142.6 146.8 158.9 170.5
S/T 0.77 0.69 0.52 0.34 0.80 0.71 0.54 0.35 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.59 0.38 0.89 0.79 0.60 0.39
∆T 23 21 17 12 23 21 17 12 23 21 17 12 23 21 18 12 23 21 17 12 21 20 16 11
HI PR 234 252 266 277 262 282 298 311 298 321 339 354 340 366 386 403 382 411 434 453 422 454 480 501
LO PR 102 109 119 127 108 115 126 134 112 120 131 139 118 126 137 146 124 132 144 153 128 136 149 158
4320
MBh 160.7 165.5 179.1 192.3 157.0 161.6 175.0 187.8 153.3 157.8 170.8 183.3 149.5 154.0 166.6 178.8 142.0 146.3 158.3 169.9 131.6 135.5 146.6 157.4
S/T 0.74 0.67 0.50 0.32 0.77 0.69 0.52 0.34 0.79 0.71 0.53 0.34 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.85 0.76 0.58 0.37
∆T 25 23 19 13 26 24 19 13 26 24 19 13 26 24 20 14 26 24 19 13 24 22 18 12
HI PR 227 244 258 269 254 274 289 302 289 311 329 343 330 355 375 391 371 399 421 439 410 441 466 486
LO PR 99 106 115 123 105 112 122 130 109 116 127 135 115 122 133 142 120 128 139 148 124 132 144 154
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) conditions High and low pressures are measured at the liquid and suction access ttings.