COOLING PERFORMANCE DATA
GPH1342M41*
MODEL: GPH1342M41*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/-2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159 63 677159 63 67715963677159636771
MBh 39.2 40.6 44.5 - 38.3 39.7 43.5 - 37.4 38.7 42.4 - 36.5 37.8 41.4 - 34.6 35.9 39.3 - 32.1 33.3 36.4 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.70 0.48 - 0.84 0.70 0.49 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
1461 KW 2.86 2.91 3.00 - 3.06 3.12 3.22 - 3.24 3.31 3.41 - 3.40 3.47 3.58 - 3.54 3.61 3.73 - 3.65 3.73 3.85 -
AMPS 12.5 12.8 13.1 - 13.4 13.7 14.0 - 14.4 14.7 15.1 - 15.2 15.5 16.0 - 16.0 16.4 16.9 - 16.9 17.2 17.8 -
HI PR 227 244 258 - 255 274 289 - 290 312 329 - 330 355 375 - 371 399 422 - 410 441 466 -
LO PR 106 113 123 - 112 119 130 - 116 124 135 - 122 130 142 - 128 136 148 - 132 141 154 -
MBh 38.1 39.4 43.2 - 37.2 38.5 42.2 - 36.3 37.6 41.2 - 35.4 36.7 40.2 - 33.6 34.9 38.2 - 31.2 32.3 35.4 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
Delta T 19 16 12 - 19 16 13 - 19 16 13 - 19 17 13 - 19 16 12 - 18 15 12 -
70 1300 KW 2.84 2.89 2.98 - 3.04 3.10 3.19 - 3.22 3.28 3.38 - 3.38 3.45 3.55 - 3.51 3.58 3.70 - 3.63 3.70 3.82 -
AMPS 12.4 12.7 13.0 - 13.3 13.5 13.9 - 14.2 14.5 15.0 - 15.1 15.4 15.8 - 15.9 16.3 16.7 - 16.7 17.1 17.6 -
HI PR 225 242 255 - 252 271 286 - 287 308 326 - 327 351 371 - 367 395 417 - 406 437 461 -
LO PR 105 111 122 - 111 118 129 - 115 122 134 - 121 129 140 - 127 135 147 - 131 139 152 -
MBh 35.1 36.4 39.9 - 34.3 35.6 39.0 - 33.5 34.7 38.0 - 32.7 33.9 37.1 - 31.0 32.2 35.2 - 28.8 29.8 32.7 -
S/T 0.67 0.56 0.39 - 0.70 0.58 0.40 - 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.77 0.65 0.45 -
Delta T 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 16 12 -
1139 KW 2.77 2.83 2.91 - 2.97 3.03 3.12 - 3.14 3.21 3.31 - 3.30 3.37 3.47 - 3.43 3.50 3.61 - 3.54 3.61 3.73 -
AMPS 12.2 12.4 12.7 - 13.0 13.2 13.6 - 13.9 14.2 14.6 - 14.7 15.0 15.5 - 15.5 15.9 16.3 - 16.3 16.7 17.2 -
HI PR 218 234 248 - 244 263 278 - 278 299 316 - 317 341 360 - 356 383 405 - 394 424 447 -
LO PR 102 108 118 - 107 114 125 - 112 119 130 - 117 125 136 - 123 131 143 - 127 135 148 -
MBh 39.9 41.0 44.4 47.7 38.9 40.1 43.4 46.6 38.0 39.1 42.4 45.5 37.1
38.2
41.3 44.4 35.2 36.3 39.3 42.1 32.6 33.6 36.4 39.0
S/T 0.830.740.560.360.860.770.580.380.88 0.79 0.600.390.91
0.82
0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42
Delta T211916112119161121 19 161121
20
16 11 21 19 16 11 20 18 15 10
1461 KW 2.882.943.023.113.093.153.243.343.27 3.34 3.443.553.43
3.50
3.61 3.72 3.57 3.64 3.76 3.88 3.68 3.76 3.88 4.01
AMPS 12.6 12.9 13.2 13.6 13.5 13.8 14.1 14.6 14.5 14.8 15.2 15.7 15.3
15.6
16.1 16.6 16.2 16.5 17.0 17.6 17.0 17.4 17.9 18.5
HI PR 229 247 260 272 257 277 292 305 292 315 332 347 333
358
379 395 375 403 426 444 414 446 471 491
LO PR 107 114 124 132 113 120 131 140 117 125 136 145 123
131
143 152 129 137 150 160 134 142 155 165
MBh 38.7 39.8 43.1 46.3 37.8 38.9 42.1 45.2 36.9 38.0 41.1 44.1 36.0
37.1
40.1 43.1 34.2 35.2 38.1 40.9 31.7 32.6 35.3 37.9
S/T 0.790.710.540.350.820.740.560.360.84 0.75 0.570.370.87
0.78
0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
Delta T222016112220171122 20 171122
20
17 12 22 20 16 11 20 19 15 11
75 1300 KW 2.862.923.003.093.063.123.223.323.24 3.31 3.413.523.40
3.47
3.58 3.69 3.54 3.61 3.73 3.84 3.66 3.73 3.85 3.97
AMPS 12.5 12.8 13.1 13.5 13.4 13.7 14.0 14.5 14.4 14.7 15.1 15.6 15.2
15.5
16.0 16.5 16.0 16.4 16.9 17.4 16.9 17.2 17.8 18.4
HI PR 227 244 258 269 255 274 289 302 290 312 329 343 330
355
375 391 371 399 422 440 410 441 466 486
LO PR 106 113 123 131 112 119 130 138 116 124 135 144 122
130
142 151 128 136 149 158 132 141 154 164
MBh 35.7 36.8 39.8 42.7 34.9 35.9 38.9 41.7 34.1 35.1 38.0 40.7 33.2
34.2
37.0 39.7 31.6 32.5 35.2 37.8 29.2 30.1 32.6 35.0
S/T 0.770.680.520.330.790.710.540.350.81 0.73 0.550.350.84
0.75
0.57 0.37 0.87 0.78 0.59 0.38 0.88 0.79 0.60 0.38
Delta T222017112221171222 21 171223
21
17 12 22 20 17 12 21 19 16 11
1139 KW 2.802.852.933.022.993.053.143.243.17 3.23 3.333.433.32
3.39
3.50 3.61 3.45 3.53 3.64 3.75 3.57 3.64 3.76 3.88
AMPS 12.3 12.5 12.8 13.2 13.1 13.3 13.7 14.1 14.0 14.3 14.7 15.2 14.8
15.2
15.6 16.1 15.7 16.0 16.5 17.0 16.5 16.8 17.3 17.9
HI PR 220 237 250 261 247 266 281 293 281 302 319 333 320
344
364 379 360 387 409 427 398 428 452 471
LO PR 103 109 119 127 108 115 126 134 113 120 131 139 118
126
137 146 124 132 144 153 128 136 149 159
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions KW = Total system power
High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors)