COOLING PERFORMANCE DATA
GPH1330M41*
MODEL: GPH1330M41*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159 63 677159 63 67715963677159636771
MBh 28.4 29.5 32.3 - 27.8 28.8 31.5 - 27.1 28.1 30.8 - 26.4 27.4 30.0 - 25.1 26.0 28.5 - 23.3 24.1 26.4 -
S/T 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.88 0.73 0.51 - 0.88 0.74 0.51 -
Delta T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 11 -
1180 KW 2.20 2.24 2.31 - 2.36 2.41 2.48 - 2.50 2.55 2.63 - 2.63 2.68 2.76 - 2.73 2.79 2.88 - 2.82 2.88 2.97 -
AMPS 9.5 9.7 9.9 - 10.1 10.3 10.6 - 10.9 11.1 11.4 - 11.5 11.7 12.0 - 12.1 12.4 12.7 - 12.7 13.0 13.4 -
HI PR 232 249 263 - 260 280 296 - 296 318 336 - 337 363 383 - 379 408 431 - 419 451 476 -
LO PR 109 116 126 - 115 122 134 - 120 127 139 - 126 134 146 - 132 140 153 - 136 145 158 -
MBh 27.6 28.6 31.3 - 26.9 27.9 30.6 - 26.3 27.3 29.9 - 25.7 26.6 29.1 - 24.4 25.3 27.7 - 22.6 23.4 25.6 -
S/T 0.74 0.61 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.84 0.70 0.48 - 0.84 0.70 0.49 -
Delta T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
70 1050 KW 2.18 2.23 2.29 - 2.34 2.39 2.46 - 2.48 2.53 2.61 - 2.60 2.66 2.74 - 2.71 2.77 2.85 - 2.80 2.86 2.95 -
AMPS 9.4 9.6 9.9 - 10.1 10.3 10.5 - 10.8 11.0 11.3 - 11.4 11.6 12.0 - 12.0 12.3 12.6 - 12.6 12.9 13.3 -
HI PR 229 247 261 - 257 277 293 - 293 315 333 - 334 359 379 - 375 404 426 - 415 446 471 -
LO PR 108 115 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 139 151 - 135 143 156 -
MBh 25.5 26.4 28.9 - 24.9 25.8 28.2 - 24.3 25.2 27.6 - 23.7 24.6 26.9 - 22.5 23.3 25.6 - 20.8 21.6 23.7 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
920 KW 2.14 2.18 2.24 - 2.29 2.33 2.41 - 2.42 2.47 2.55 - 2.54 2.60 2.68 - 2.64 2.70 2.78 - 2.73 2.79 2.88 -
AMPS 9.2 9.4 9.7 - 9.8 10.0 10.3 - 10.5 10.7 11.0 - 11.1 11.4 11.7 - 11.7 12.0 12.3 - 12.3 12.6 12.9 -
HI PR 223 240 253 - 250 269 284 - 284 306 323 - 324 348 368 - 364 392 414 - 402 433 457 -
LO PR 105 111 121 - 110 117 128 - 115 122 133 - 121 128 140 - 126 134 147 - 131 139 152 -
MBh28.929.832.234.628.229.131.533.827.6 28.4 30.733.026.9
27.7
30.0 32.2 25.5 26.3 28.5 30.5 23.7 24.4 26.4 28.3
S/T 0.88 0.78 0.59 0.38 0.91 0.81 0.61 0.40 0.93 0.83 0.63 0.41 0.96
0.86
0.65 0.42 1.00 0.89 0.68 0.43 1.00 0.90 0.68 0.44
Delta T201815102018151020 18 151020
19
15 10 20 18 15 10 18 17 14 10
1180 KW 2.22 2.26 2.33 2.40 2.38 2.43 2.50 2.58 2.52 2.57 2.65 2.74 2.65
2.70
2.79 2.88 2.75 2.81 2.90 2.99 2.84 2.91 3.00 3.10
AMPS 9.6 9.8 10.0 10.3 10.2 10.4 10.7 11.0 10.9 11.2 11.5 11.8 11.6
11.8
12.1 12.5 12.2 12.5 12.8 13.2 12.8 13.1 13.5 13.9
HI PR 234 252 266 277 263 283 299 311 299 322 340 354 340
366
387 403 383 412 435 454 423 455 481 501
LO PR 110 117 128 136 116 124 135 144 121 128 140 149 127
135
147 157 133 141 154 164 137 146 160 170
MBh28.128.931.333.627.428.230.532.826.8 27.5 29.832.026.1
26.9
29.1 31.2 24.8 25.5 27.6 29.7 23.0 23.6 25.6 27.5
S/T 0.84 0.75 0.57 0.36 0.87 0.77 0.59 0.38 0.89 0.79 0.60 0.39 0.92
0.82
0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42
Delta T211915112119161121 19 161121
19
16 11 21 19 16 11 19 18 15 10
75 1050 KW 2.20 2.24 2.31 2.38 2.36 2.41 2.48 2.56 2.50 2.55 2.63 2.72 2.63
2.68
2.76 2.85 2.73 2.79 2.88 2.97 2.82 2.88 2.97 3.07
AMPS 9.5 9.7 9.9 10.3 10.1 10.3 10.6 10.9 10.9 11.1 11.4 11.7 11.5
11.7
12.0 12.4 12.1 12.4 12.7 13.1 12.7 13.0 13.4 13.8
HI PR 232 249 263 275 260 280 296 308 296 318 336 351 337
363
383 399 379 408 431 449 419 451 476 496
LO PR 109 116 126 135 115 122 134 142 120 127 139 148 126
134
146 155 132 140 153 163 136 145 158 168
MBh25.926.728.931.025.326.028.230.324.7 25.4 27.529.524.1
24.8
26.8 28.8 22.9 23.6 25.5 27.4 21.2 21.8 23.6 25.4
S/T 0.81 0.72 0.55 0.35 0.83 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88
0.79
0.60 0.38 0.92 0.82 0.62 0.40 0.92 0.83 0.63 0.40
Delta T211916112119161121 19 161121
20
16 11 21 19 16 11 20 18 15 10
920 KW 2.15 2.19 2.26 2.33 2.31 2.35 2.42 2.50 2.44 2.49 2.57 2.65 2.56
2.62
2.70 2.78 2.67 2.72 2.81 2.90 2.75 2.81 2.90 3.00
AMPS 9.3 9.5 9.7 10.0 9.9 10.1 10.4 10.7 10.6 10.8 11.1 11.5 11.2
11.4
11.8 12.1 11.8 12.1 12.4 12.8 12.4 12.7 13.0 13.5
HI PR 225 242 256 267 252 272 287 299 287 309 326 340 327
352
371 387 368 396 418 436 406 437 462 481
LO PR 106 112 123 131 112 119 130 138 116 123 135 143 122
130
141 151 128 136 148 158 132 140 153 163
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions KW = Total system power
High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors)