Goodman Mfg RT6332013r1 Heat Pump User Manual


 
13
COOLING PERFORMANCE DATA
GPH1324M41*
MODEL: GPH1324M41*
EXPANDED PERFORMANCE DATA
COOLING OPERATION
Design Subcooling, 10 +/-2 °F @ the liquid access fitting connection AHRI 95 test conditions. Design Superheat 10 +/- 2 °F @ the compressor suction access fitting connection.
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB*Airflow 596367715963677159 63 677159 63 67715963677159636771
MBh 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.9 22.7 24.8 - 20.8 21.5 23.6 - 19.3 20.0 21.9 -
S/T 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.88 0.73 0.51 - 0.89 0.74 0.51 -
Delta T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
927 KW 1.69 1.73 1.78 - 1.82 1.85 1.91 - 1.93 1.97 2.03 - 2.02 2.06 2.13 - 2.10 2.15 2.21 - 2.17 2.22 2.29 -
AMPS 7.4 7.5 7.7 - 7.8 8.0 8.2 - 8.4 8.5 8.8 - 8.8 9.0 9.3 - 9.3 9.5 9.8 - 9.8 10.0 10.3 -
HI PR 231 249 263 - 259 279 295 - 295 317 335 - 336 361 382 - 378 407 429 - 417 449 474 -
LO PR 113 120 131 - 119 127 138 - 124 132 144 - 130 138 151 - 136 145 158 - 141 150 164 -
MBh 22.8 23.7 25.9 - 22.3 23.1 25.3 - 21.8 22.6 24.7 - 21.2 22.0 24.1 - 20.2 20.9 22.9 - 18.7 19.4 21.2 -
S/T 0.74 0.61 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.84 0.70 0.48 - 0.84 0.71 0.49 -
Delta T 19 16 12 - 19 16 12 - 19 16 12 - 19 17 13 - 19 16 12 - 18 15 12 -
70 825 KW 1.68 1.72 1.77 - 1.80 1.84 1.90 - 1.91 1.95 2.01 - 2.00 2.05 2.11 - 2.09 2.13 2.20 - 2.15 2.20 2.27 -
AMPS 7.3 7.4 7.6 - 7.8 7.9 8.1 - 8.3 8.5 8.7 - 8.8 9.0 9.2 - 9.2 9.4 9.7 - 9.7 9.9 10.2 -
HI PR 229 246 260 - 257 276 292 - 292 314 332 - 333 358 378 - 374 403 425 - 413 445 470 -
LO PR 111 119 129 - 118 125 137 - 122 130 142 - 129 137 149 - 135 143 157 - 139 148 162 -
MBh 21.1 21.8 23.9 - 20.6 21.3 23.4 - 20.1 20.8 22.8 - 19.6 20.3 22.3 - 18.6 19.3 21.1 - 17.3 17.9 19.6 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.43 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -
Delta T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 17 13 - 18 15 12 -
723 KW 1.64 1.68 1.73 - 1.76 1.80 1.85 - 1.87 1.90 1.96 - 1.96 2.00 2.06 - 2.04 2.08 2.14 - 2.10 2.15 2.22 -
AMPS 7.1 7.3 7.5 - 7.6 7.7 8.0 - 8.1 8.3 8.5 - 8.6 8.8 9.0 - 9.0 9.2 9.5 - 9.5 9.7 10.0 -
HI PR 222 239 252 - 249 268 283 - 283 305 322 - 323 347 367 - 363 390 412 - 401 431 456 -
LO PR 108 115 126 - 114 122 133 - 119 126 138 - 125 133 145 - 131 139 152 - 135 144 157 -
MBh 23.9 24.6 26.7 28.6 23.4 24.1 26.0 27.9 22.8 23.5 25.4 27.3 22.2
22.9
24.8 26.6 21.1 21.8 23.6 25.3 19.6 20.2 21.8 23.4
S/T 0.88 0.78 0.59 0.38 0.91 0.81 0.61 0.40 0.93 0.83 0.63 0.41 0.96
0.86
0.65 0.42 1.00 0.89 0.68 0.43 1.00 0.90 0.68 0.44
Delta T211916112119161121 19 161121
20
16 11 21 19 16 11 19 18 15 10
927 KW 1.71 1.74 1.79 1.85 1.83 1.87 1.93 1.99 1.94 1.98 2.04 2.11 2.04
2.08
2.14 2.21 2.12 2.16 2.23 2.30 2.19 2.24 2.31 2.38
AMPS 7.4 7.6 7.7 8.0 7.9 8.0 8.3 8.5 8.4 8.6 8.8 9.1 8.9
9.1
9.4 9.7 9.4 9.6 9.9 10.2 9.9 10.1 10.4 10.7
HI PR 233 251 265 277 262 282 298 310 298 321 338 353 339
365
386 402 382 411 434 452 422 454 479 500
LO PR 114 121 132 141 120 128 140 149 125 133 145 154 131
140
152 162 138 146 160 170 142 151 165 176
MBh 23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1 22.8 24.7 26.5 21.6
22.2
24.1 25.8 20.5 21.1 22.9 24.5 19.0 19.6 21.2 22.7
S/T 0.84 0.75 0.57 0.36 0.87 0.77 0.59 0.38 0.89 0.79 0.60 0.39 0.92
0.82
0.62 0.40 0.95 0.85 0.64 0.41 0.96 0.86 0.65 0.42
Delta T222016112220171122 20 171122
20
17 11 22 20 16 11 20 19 15 11
75 825 KW 1.70 1.73 1.78 1.83 1.82 1.85 1.91 1.97 1.93 1.97 2.03 2.09 2.02
2.06
2.13 2.20 2.10 2.15 2.21 2.29 2.17 2.22 2.29 2.36
AMPS 7.4 7.5 7.7 7.9 7.8 8.0 8.2 8.4 8.4 8.5 8.8 9.1 8.8
9.0
9.3 9.6 9.3 9.5 9.8 10.1 9.8 10.0 10.3 10.6
HI PR 231 249 263 274 259 279 295 307 295 317 335 350 336
361
382 398 378 407 429 448 418 449 474 495
LO PR 113 120 131 139 119 127 138 147 124 132 144 153 130
138
151 161 136 145 158 168 141 150 164 174
MBh 21.4 22.1 23.9 25.6 20.9 21.6 23.3 25.0 20.4 21.0 22.8 24.4 19.9
20.5
22.2 23.8 18.9 19.5 21.1 22.7 17.5 18.1 19.6 21.0
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88
0.79
0.60 0.39 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
Delta T222017112220171222 21 171222
21
17 12 22 20 17 12 21 19 16 11
723 KW 1.66 1.69 1.74 1.79 1.78 1.81 1.87 1.92 1.88 1.92 1.98 2.04 1.97
2.01
2.08 2.14 2.05 2.10 2.16 2.23 2.12 2.16 2.23 2.31
AMPS 7.2 7.3 7.5 7.7 7.7 7.8 8.0 8.3 8.2 8.4 8.6 8.8 8.6
8.8
9.1 9.4 9.1 9.3 9.6 9.9 9.6 9.8 10.0 10.4
HI PR 224 241 255 266 252 271 286 298 286 308 325 339 326
351
370 386 367 394 417 434 405 436 460 480
LO PR 109 116 127 135 115 123 134 143 120 128 139 148 126
134
146 156 132 140 153 163 137 145 159 169
* Entering Indoor Dry Bulb Temperature NOTE: Shaded area is ACCA (TVA) conditions KW = Total system power
High and low pressures are measured at the liquid and suction access fittings. AMPS: Unit amps (comp.+ evaporator + condenser fan motors)