Goodman Mfg GSC13 Air Conditioner User Manual


 
6 www.goodmanmfg.com SS-GSC13
Product SPecificationS
expAnded rAtinGS — GSC130241f*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
70
700
MBh 20.0 20.8 22.7 - 19.6 20.3 22.2 - 19.1 19.8 21.7 - 18.6 19.3 21.1 - 17.7 18.3 20.1 - 16.4 17.0 18.6 -
S/T 0.67 0.56 0.38 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.76 0.64 0.44 -
∆T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
kW 1.48 1.52 1.57 - 1.61 1.65 1.71 - 1.73 1.77 1.83 - 1.83 1.87 1.94 - 1.91 1.96 2.03 - 1.99 2.04 2.11 -
Amps 7.0 7.1 7.3 - 7.5 7.6 7.8 - 8.0 8.1 8.4 - 8.4 8.6 8.9 - 8.9 9.1 9.4 - 9.4 9.6 9.8 -
HI PR 134 144 152 - 150 162 171 - 171 184 194 - 195 210 221 - 219 236 249 - 242 261 275 -
LO PR 57 61 66 - 60 64 70 - 63 67 73 - 66 70 77 - 69 73 80 - 71 76 83 -
800
MBh 21.7 22.5 24.6 - 21.2 22.0 24.1 - 20.7 21.4 23.5 - 20.2 20.9 22.9 - 19.2 19.9 21.8 - 17.8 18.4 20.2 -
S/T 0.69 0.58 0.40 - 0.71 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.79 0.66 0.45 - 0.79 0.66 0.46 -
∆T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 12 - 17 15 11 - 16 14 11 -
kW 1.52 1.56 1.62 - 1.66 1.70 1.76 - 1.78 1.82 1.89 - 1.88 1.93 2.00 - 1.97 2.02 2.09 - 2.05 2.10 2.17 -
Amps 7.2 7.3 7.5 - 7.6 7.8 8.0 - 8.2 8.3 8.6 - 8.6 8.8 9.1 - 9.1 9.3 9.6 - 9.6 9.8 10.1 -
HI PR 138 149 157 - 155 167 176 - 176 190 200 - 201 216 228 - 226 243 257 - 250 269 284 -
LO PR 59 63 68 - 62 66 72 - 65 69 75 - 68 72 79 - 71 76 83 - 74 78 86 -
900
MBh 22.3 23.2 25.4 - 21.8 22.6 24.8 - 21.3 22.1 24.2
- 20.8 21.5 23.6 - 19.7 20.5 22.4 - 18.3 19.0 20.8 -
S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -
∆T 17 14 11 - 17 14 11 - 17 14 11 - 17 15 11 - 17 14 11 - 16 13 10 -
kW 1.54 1.58 1.63 - 1.67 1.71 1.78 - 1.79 1.84 1.90 - 1.90 1.95 2.02 - 1.99 2.04 2.11 - 2.07 2.12 2.19 -
Amps
7.2 7.3 7.5 - 7.7 7.8 8.1 - 8.2 8.4 8.6 - 8.7 8.9 9.2 - 9.2 9.4 9.7 - 9.7 9.9 10.2 -
HI PR 140 150 159 - 157 169 178 - 178 192 202 - 203 218 231 - 228 246 259 - 252 271 287 -
LO PR 59 63 69 - 63 67 73 - 65 69 76 - 69 73 80 - 72 76 84 - 74 79 86 -
75
700
MBh 20.4 21.0 22.7 24.4 19.9 20.5 22.2 23.8 19.4 20.0 21.6 23.2 18.9 19.5 21.1 22.7 18.0 18.5 20.1 21.5 16.7 17.2 18.6 19.9
S/T 0.76 0.68 0.51 0.33 0.78 0.70 0.53 0.34 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.87 0.78 0.59 0.38
∆T 20 19 15 11 20 19 15 11 20 19 15 11 21 19 16 11 20 19 15 11 19 17 14 10
kW 1.50 1.53 1.59 1.65 1.63 1.67 1.73 1.79 1.74 1.79 1.85 1.92 1.85 1.89 1.96 2.03 1.93 1.98 2.05 2.13 2.01 2.06 2.13 2.21
Amps 7.0 7.2 7.4 7.6 7.5 7.7 7.9 8.1 8.0 8.2 8.4 8.7 8.5 8.7 8.9 9.2 9.0 9.2 9.4 9.7 9.4 9.6 9.9 10.2
HI PR 135 146 154 161 152 164 173 180 173 186 196 205 197 212 224 233 222 238 252 263 245 263 278 290
LO PR 58 61 67 71 61 65 71 75 63 67 74 78 67 71 77 82 70 74 81 86 72 77 84 89
800
MBh 22.1 22.7 24.6 26.4 21.5 22.2 24.0 25.8 21.0 21.7 23.4 25.2 20.5 21.1 22.9 24.5 19.5 20.1 21.7 23.3 18.1 18.6 20.1 21.6
S/T 0.78 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.81 0.61 0.39
∆T 20 18 15 10 20 19 15 10
20 19 15 10 20 19 15 11 20 18 15 10 19 17 14 10
kW 1.54 1.58 1.63 1.69 1.67 1.71 1.78 1.84 1.79 1.84 1.90 1.97 1.90 1.95 2.02 2.09 1.99 2.04 2.11 2.19 2.07 2.12 2.20 2.28
Amps
7.2 7.3 7.5 7.8 7.7 7.8 8.1 8.3 8.2 8.4 8.6 8.9 8.7 8.9 9.2 9.5 9.2 9.4 9.7 10.0 9.7 9.9 10.2 10.5
HI PR 140 150 159 166 157 169 178 186 178 192 203 211 203 218 231 241 228 246 260 271 252 272 287 299
LO PR 59 63 69 74 63 67 73 78 65 69 76 81 69 73 80 85 72 77 84 89 74 79 86 92
900
MBh 22.7 23.4 25.3 27.2 22.2 22.8 24.7 26.5 21.7 22.3 24.1 25.9 21.1 21.8 23.6 25.3 20.1 20.7 22.4 24.0 18.6 19.1 20.7 22.2
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.94 0.84 0.64 0.41
∆T 19 18 14 10 19 18 15 10 19 18 15 10 19 18 15 10 19 18 14 10 18 17 14 9
kW 1.55 1.59 1.65 1.71 1.69 1.73 1.79 1.86 1.81 1.85 1.92 1.99 1.92 1.96 2.04 2.11 2.01 2.06 2.13 2.21 2.09 2.14 2.22 2.30
Amps 7.3 7.4 7.6 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.7 9.0 8.8 9.0 9.2 9.5 9.3 9.5 9.7 10.1 9.7 10.0 10.3 10.6
HI PR 141 152 160 167 158 170 180 188 180 194 205 213 205 221 233 243 231 248 262 273 255 274 290 302
LO PR 60 64 70 74 63 68 74 79 66 70 77 82 69 74 80 86 73 77 84 90 75 80 87 93
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power