Goodman Mfg Condensing Units Air Conditioner User Manual


 
11
COOLING PERFORMANCE DATA
CKF36-5*
MODEL: CKF36-5* / AR36-00-2 COOLING OPERATION
Outdoor Ambient Temperature
65°F 75°F 85°F 95°F 105°F 115°F 118°F 125°F
Entering Indoor Wet Bulb Temperature
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 53 67 71 59 63 67 71
MBh 31.9 33.0 36.2 - 31.1 32.3 35.3 - 30.4 31.5 34.5 - 29.6 30.7 33.7 - 28.2 29.2 32.0 - 26.1 27.0 29.6 - 25.4 26.3 28.8 - 25.1 26.0 28.5 -
S/T 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.83 0.69 0.48 - 0.87 0.72 0.50 - 0.88 0.74 0.51 -
DT 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 11 - 16 14 11 - 17 14 11 -
1229 KW 2.43 2.48 2.56 - 2.77 2.84 2.93 - 3.06 3.13 3.24 - 3.36 3.44 3.56 - 3.63 3.71 3.85 - 3.88 3.97 4.11 - 4.25 4.35 4.51 - 4.41 4.52 4.68 -
AMPS 5.9 6.0 6.2 - 6.3 6.4 6.6 - 6.7 6.9 7.1 - 7.1 7.3 7.5 - 7.5 7.7 7.9 - 7.9 8.1 8.3 - 7.8 8.0 8.2 - 7.8 7.9 8.2 -
HI PR 162 174 184 - 182 196 206 - 207 222 235 - 235 253 267 - 265 285 301 - 293 315 332 - 321 346 365 - 334 359 379 -
LO PR 55 59 64 - 59 62 68 - 61 65 71 - 64 68 74 - 67 71 78 - 69 74 81 - 74 79 86 - 76 81 89 -
MBh 31.4 32.5 35.7 - 30.7 31.8 34.8 - 29.9 31.0 34.0 - 29.2 30.3 33.2 - 27.7 28.8 31.5 - 25.7 26.6 29.2 - 25.0 25.9 28.4 - 24.7 25.6 28.0 -
S/T 0.69 0.58 0.40 - 0.71 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.79 0.66 0.46 - 0.83 0.69 0.48 - 0.85 0.71 0.49 -
DT 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 - 17 15 11 - 17 15 11 -
70 1100 KW 2.41 2.47 2.55 - 2.76 2.82 2.92 - 3.04 3.12 3.22 - 3.34 3.42 3.54 - 3.61 3.69 3.82 - 3.85 3.94 4.08 - 4.22 4.33 4.48 - 4.38 4.49 4.65 -
AMPS 5.9 6.0 6.1 - 6.2 6.4 6.5 - 6.7 6.8 7.0 - 7.1 7.2 7.4 - 7.5 7.6 7.8 - 7.8 8.0 8.2 - 7.8 7.9 8.2 - 7.7 7.9 8.1 -
HI PR 161 173 183 - 180 194 205 - 205 221 233 - 234 252 266 - 263 283 299 - 291 313 330 - 319 343 363 - 331 357 377 -
LO PR 55 59 64 - 58 62 68 - 60 64 70 - 64 68 74 - 67 71 77 - 69 73 80 - 74 78 86 - 76 81 88 -
MBh 29.8 30.9 33.9 - 29.1 30.2 33.1 - 28.4 29.5 32.3 - 27.7 28.8 31.5 - 26.4 27.3 29.9 - 24.4 25.3 27.7 - 23.7 24.6 27.0 - 23.5 24.3 26.6 -
S/T 0.66 0.55 0.38 - 0.68 0.57 0.40 - 0.70 0.59 0.41 - 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 -
DT 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 15 12 - 18 15 12 - 18 16 12 -
971 KW 2.37 2.43 2.51 - 2.71 2.77 2.86 - 2.99 3.06 3.17 - 3.28 3.36 3.47 - 3.54 3.63 3.75 - 3.78 3.87 4.01 - 4.15 4.25 4.40 - 4.30 4.41 4.57 -
AMPS 5.8 5.9 6.0 - 6.1 6.3 6.4 - 6.6 6.7 6.9 - 7.0 7.1 7.3 - 7.3 7.5 7.7 - 7.7 7.9 8.1 - 7.6 7.8 8.0 - 7.6 7.8 8.0 -
HI PR 158 170 179 - 177 190 201 - 201 216 229 - 229 246 260 - 258 277 293 - 285 306 324 - 313 337 355 - 325 349 369 -
LO PR 54 57 63 - 57 61 66 - 59 63 69 - 62 66 72 - 65 69 76 - 67 72 78 - 72 77 84 - 74 79 86 -
MBh 32.4 33.4 36.1 38.8 31.7 32.6 35.3 37.9 30.9 31.8 34.4 37.0 30.1 31.0 33.6 36.1 28.6 29.5 31.9 34.3 26.5 27.3 29.6 31.7 25.8 26.6 28.8 30.9 25.5 26.2 28.4 30.5
S/T 0.82 0.73 0.55 0.4 0.85 0.76 0.57 0.4 0.87 0.78 0.59 0.4 0.90 0.80 0.61 0.4 0.93 0.83 0.63 0.4 0.94 0.84 0.64 0.4 0.98 0.88 0.67 0.4 1.00 0.90 0.68 0.4
DT 20 18 15 10 20 18 15 10 20 18 15 10 20 19 15 11 20 18 15 10 19 17 14 9.7 19 17 14 9.9 19 18 14 10.0
1229 KW 2.45 2.50 2.59 2.7 2.80 2.86 2.96 3.1 3.09 3.16 3.27 3.4 3.39 3.47 3.59 3.7 3.66 3.75 3.88 4.0 3.91 4.01 4.15 4.3 4.29 4.39 4.55 4.7 4.45 4.56 4.73 4.9
AMPS 5.9 6.0 6.2 6.4 6.3 6.5 6.6 6.8 6.8 6.9 7.1 7.3 7.2 7.3 7.5 7.8 7.6 7.7 8.0 8.2 8.0 8.1 8.4 8.6 7.9 8.0 8.3 8.5 7.8 8.0 8.2 8.5
HI PR 164 176 186 193.9 184 198 209 217.5 209 225 237 247.4 238 256 270 281.8 267 288 304 317.0 296 318 336 350.3 325 349 369 384.8 337 363 383 399.5
LO PR 56 60 65 69.3 59 63 69 73.2 62 65 71 76.1 65 69 75 79.9 68 72 79 83.8 70 75 81 86.7 75 80 87 92.8 77 82 90 95.4
MBh 31.9 32.9 35.6 38.2 31.2 32.1 34.8 37.3 30.4 31.3 33.9 36.4 29.7 30.6 33.1 35.5 28.2 29.1 31.4 33.7 26.1 26.9 29.1 31.3 25.4 26.2 28.3 30.4 25.1 25.9 28.0 30.0
S/T 0.78 0.70 0.53 0.3 0.81 0.73 0.55 0.4 0.83 0.74 0.56 0.4 0.86 0.77 0.58 0.4 0.89 0.80 0.60 0.4 0.90 0.80 0.61 0.4 0.94 0.84 0.64 0.4 0.96 0.86 0.65 0.4
DT 21 19 16 11 21 19 16 11 21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10.2 20 18 15 10.4 20 19 15 10.5
75 1100 KW 2.43 2.49 2.57 2.7 2.78 2.84 2.94 3.0 3.07 3.14 3.25 3.4 3.37 3.45 3.57 3.7 3.64 3.72 3.86 4.0 3.89 3.98 4.12 4.3 4.26 4.37 4.52 4.7 4.43 4.53 4.70 4.9
AMPS 5.9 6.0 6.2 6.4 6.3 6.4 6.6 6.8 6.7 6.9 7.1 7.3 7.1 7.3 7.5 7.7 7.5 7.7 7.9 8.2 7.9 8.1 8.3 8.6 7.8 8.0 8.2 8.5 7.8 8.0 8.2 8.5
HI PR 162 175 185 192.5 182 196 207 216.0 207 223 236 245.7 236 254 268 279.8 266 286 302 314.8 293 316 333 347.8 322 347 366 382.1 335 360 380 396.8
LO PR 56 59 65 68.8 59 63 68 72.7 61 65 71 75.6 64 68 75 79.4 67 72 78 83.2 70 74 81 86.1 74 79 86 92.1 77 81 89 94.7
MBh 30.3 31.2 33.8 36.3 29.6 30.5 33.0 35.4 28.9 29.8 32.2 34.6 28.2 29.1 31.4 33.7 26.8 27.6 29.9 32.1 24.8 25.6 27.7 29.7 24.2 24.9 26.9 28.9 23.9 24.6 26.6 28.5
S/T 0.75 0.67 0.51 0.3 0.78 0.70 0.53 0.3 0.80 0.71 0.54 0.3 0.82 0.74 0.56 0.4 0.85 0.76 0.58 0.4 0.86 0.77 0.58 0.4 0.90 0.81 0.61 0.4 0.92 0.82 0.62 0.4
DT 22 20 16 11 22 20 16 11 22 20 16 11 22 20 17 11 22 20 16 11 20 19 15 10.5 21 19 16 10.8 21 19 16 10.8
971 KW 2.39 2.45 2.53 2.6 2.73 2.80 2.89 3.0 3.02 3.09 3.19 3.3 3.31 3.39 3.50 3.6 3.57 3.66 3.79 3.9 3.82 3.91 4.05 4.2 4.19 4.29 4.44 4.6 4.34 4.45 4.61 4.8
AMPS 5.8 5.9 6.1 6.3 6.2 6.3 6.5 6.7 6.6 6.8 7.0 7.2 7.0 7.2 7.4 7.6 7.4 7.6 7.8 8.0 7.8 7.9 8.2 8.5 7.7 7.9 8.1 8.4 7.7 7.8 8.1 8.3
HI PR 159 171 181 188.7 179 192 203 211.7 203 219 231 240.8 231 249 263 274.2 260 280 296 308.5 288 309 327 340.9 316 340 359 374.4 328 353 373 388.8
LO PR 55 58 63 67.5 58 61 67 71.3 60 64 70 74.1 63 67 73 77.8 66 70 77 81.5 68 73 79 84.3 73 78 85 90.3 75 80 87 92.8
Shaded area is ACCA (TVA) conditions IDB: Entering Indoor Dry Bulb Temperature KW=Total system power AMPS=outdoor unit amps (comp.+fan)
High and low pressures are measured at the liquid and suction service valves.
EXPANDED PERFORMANCE DATA