Goodman Mfg A/GPG13 M Air Conditioner User Manual


 
24
NR = Heating Temperature Rise Not Recommended.
NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation,
external static pressure should not exceed 0.5" w.c.
BLOWER PERFORMANCE DATA - COOLING SPEEDS THREE PHASE
Unit
Static CFM Watts RPM Amps CFM Watts RPM Amps CFM Watts RPM Amps
0.1 1,655 604 878 2.67 1,469 494 804 2.24 1,100 342 665 1.57
0.2 1,579 587 903 2.68 1,409 480 833 2.15 1,037 335 697 1.52
0.3 1,483 567 925 2.62 1,327 459 866 2.08 991 320 760 1.45
0.4 1,407 547 953 2.53 1,257 442 903 2 926 308 818 1.39
0.5 1,329 522 980 2.44 1,163 419 942 1.89 831 290 872 1.32
0.6 1,210 498 1,004 2.35 1,094 398 968 1.8 773 279 902 1.25
0.7 1,036 464 1,033 2.24 942 363 1,002 1.65 669 260 945 1.17
0.8------------
Unit
Static CFM WATTS AMPS CFM WATTS AMPS
0.1 -------- -------- -------- -------- -------- --------
0.2 1,593 449 3.55 1,669 532 4.22
0.3
1,545 463 3.69 1,654 239 4.25
0.4
1,506 476 3.82 1,610 551 4.30
0.5 1,448 481 3.87 1,545 557 4.36
0.6 1,400 493 3.95 1,512 566 4.41
0.7 1,341 502 4.00 1,433 578 4.59
0.8
1289 511 4.11 1,392 591 4.65
Unit
Static CFM WATTS RPM AMPS CFM WATTS RPM AMP
S
0.1 1942 649 993 4.83 2067 792 1054 5.81
0.2 1883 657 1010 4.87 2030 811 1077 5.85
0.3 1859 670 1029 4.96 1982 814 1088 5.88
0.4 1827 675 1047 4.97 1909 808 1101 5.86
0.5 1749 683 1069 4.99 1842 798 1110 5.85
0.6 1706 693 1083 5.10 1789 772 1117 5.65
0.7 1655 703 1104 5.12 1703 763 1129 5.58
0.8 1588 705 1120 5.11 1618 732 1135 5.29
GPG1360***M43A* - COOLING SPEEDS
T4 (Cooling Speed) T5 (Cooling Speed)
T4 COOLING SPEED T5 COOLING SPEED
GPG1348***M43A* - Rise Range: 45° - 75°
GPG1336***M43A* - COOLING SPEEDS
HIGH (Cooling Speed) MEDIUM (Cooling Speed) LOW (Cooling Speed)