BLOWER PERFORMANCE DATA - SINGLE PHASE
NR = Heating Temperature Rise Not Recommended.
NOTE: The shaded area indicates ranges in excess of maximum external static pressure allowable when heating. For satisfactory operation,
external static pressure should not exceed 0.5" w.c.
Unit
Static CFM WATTS AMPS RISE CFM WATTS AMPS RISE CFM WATTS AMPS RISE
0.1 1,100 340 1.55 46 1,450 480 2.15 35 1,575 585 2.64 NR
0.2 1,040 325 1.49 49 1,390 460 2.06 37 1,515 565 2.58 NR
0.3 1,000 320 1.44 51 1,300 445 1.98 39 1,430 550 2.50 36
0.4
925 305 1.38 55 1,215 425 1.89
42
1,340 525 2.42
38
0.5
860 290 1.32 59 1,115 395 1.79
46
1,240 505 2.34
41
0.6 800 275 1.22 64 1,030 375 1.71 50 1,130 465 2.22 45
0.7 690 255 1.16 NR 945 350 1.60 54 1,010 450 2.18 51
0.8
-------- -------- -------- NR 860 335 1.54
59
910 430 2.12
56
Unit
Static CFM WATTS AMPS RISE CFM WATTS AMPS RISE CFM WATTS AMPS RISE
0.1 1,100 340 1.55 62 1,450 480 2.15 47 1,575 585 2.64 NR
0.2 1,040 325 1.49 66 1,390 460 2.06 49 1,515 565 2.58 45
0.3 1,000 320 1.44 68 1,300 445 1.98 52 1,430 550 2.50 48
0.4
925 305 1.38 74 1,215 425 1.89
56
1,340 525 2.42
51
0.5
860 290 1.32 NR 1,115 395 1.79
61
1,240 505 2.34
55
0.6 800 275 1.22 NR 1,030 375 1.71 66 1,130 465 2.22 60
0.7 690 255 1.16 NR 945 350 1.60 72 1,010 450 2.18 67
0.8
-------- -------- -------- NR 860 335 1.54
NR
910 430 2.12
75
*PG1342070M41A* - Rise Range: 35° - 65°
LOW MEDIUM HIGH
*PG1342090M41A* - Rise Range: 45° - 75°
LOW MEDIUM HIGH
REMOVED AA & USED A*
Unit
Static CFM WATTS AMPS RISE CFM WATTS AMPS RISE CFM WATTS AMPS RISE
0.1 1,029 346 1.51 34 1,337 471 2.08 NR 1,462 596 2.64 NR
0.2 982 334 1.46 35 1,265 452 2.01 NR 1,398 563 2.58 NR
0.3 946 329 1.40 36 1,227 448 1.97 NR 1,326 550 2.50 NR
0.4
888 313 1.38
39
1,159 429 1.87 30 1,260 534 2.42 NR
0.5
823 304 1.29
42
1,073 405 1.73 32 1,188 513 2.34 NR
0.6 750 287 1.23 46 1,008 393 1.71 34 1,090 496 2.22 32
0.7 668 271 1.16 52 895 371 1.61 39 997 478 2.18 35
0.8
454 23
8
1.00 NR 760 346 1.4
9
4
5
85
2
454 2.12 40
Unit
Static CFM WATTS AMPS RISE CFM WATTS AMPS RISE CFM WATTS AMPS RISE
0.1 1,029 346 1.51 50 1,337 471 2.08 39 1,462 596 2.64 35
0.2 982 334 1.46 53 1,265 452 2.01 41 1,398 563 2.58 37
0.3 946 329 1.40 55 1,227 448 1.97 42 1,326 550 2.50 39
0.4 888 313 1.38 58 1,159 429 1.87 45 1,260 534 2.42 41
0.5 823 304 1.29 63 1,073 405 1.73 48 1,188 513 2.34 44
0.6 750 287 1.23 NR 1,008 393 1.71 51 1,090 496 2.22 47
0.7
668 271 1.16 NR 895 371 1.61
58
997 478 2.18 52
0.8
454 238 1.00 NR 760 346 1.49
68
852 454 2.12 61
Unit
Static CFM WATTS AMPS RISE CFM WATTS AMPS RISE CFM WATTS AMPS RISE
0.1 1,029 346 1.51 50 1,337 471 2.08 NR 1,462 596 2.64 NR
0.2 982 334 1.46 53 1,265 452 2.01 NR 1,398 563 2.58 NR
0.3 946 329 1.40 55 1,227 448 1.97 NR 1,326 550 2.50 NR
0.4
888 313 1.38 58 1,159 429 1.87
45
1,260 534 2.42
NR
0.5
823 304 1.29 63 1,073 405 1.73
48
1,188 513 2.34
NR
0.6 750 287 1.23 69 1,008 393 1.71 51 1,090 496 2.22 47
0.7 668 271 1.16 NR 895 371 1.61 58 997 478 2.18 52
0.8
454 23
8
1.00 NR 760 346 1.4
9
68
85
2
454 2.12
61
*PG1336045M41A* - Rise Range: 30 -60°
LOW MEDIUM HIGH
*PG1336070M41A* - Rise Range: 35° -65°
LOW MEDIUM HIGH
*PG1336090M41A* - Rise Range: 45° -75°
LOW MEDIUM HIGH