Genie PMX-IC B Garage Door Opener User Manual


 
WARNING
During the following steps, the motor protector may
open. Wait about 20 minutes for protector to reset.
1. Adjusting the OPEN limit switch (Fig. 8-1).
Run door to open position by pushing wall control.
Locate curved OPENlimit adjustment slot on
back of power head.
Look into slot for pinion screw.
Insert a screwdriver and turn pinion screw.
clockwise to open more.
counterclockwise to open less.
2. Test door operator. Use wall control to run
door open and close.
3. Repeat step as necessary to properly set
OPEN limit switch.
4. Adjust the CLOSE limit switch (Fig. 8-1).
Run door fully closed by pushing wall control.
Locate curved CLOSElimit adjustment slot on
back of power head.
Look into slot for pinion screw.
Insert a screwdriver and turn pinion screw.
counterclockwise to close more.
clockwise to close less.
5. Test door operator. Use wall control to run door
open and close
6. Repeat step as necessary to properly set
CLOSE limit switch
7. Perform CONTACT REVERSE
Moving door can cause serious injury or death
Keep people clear of opening while door is moving.
Do Not allow children to play with remote controls.
If safety reverse does not work properly:
Close door and disconnect operator using
emergency release.
Do not use door operator or remote controls
Refer to door and door operator owners
Manuals before attempting any repairs
NOTE: Factory sets different codes for each remote
control.
Remote controls will not work if STBs malfunction
When programming remote control keep at least 24
inches away from antenna.
1. Program one-button remote (Fig. 9-1)
Locate learn code button and learn indicator on
power head.
Remove lens cover on back of power head.
Press and release learn code button on
power head.
LED on power head blinks 2 times per second.
One-Button Remote Control*
Multi-Button Remote Control*
Complete with
Battery
Actual picture may vary by model
NEC
CLASS 2
1
2
3
4
5
6
MORE
FORCE
PUSH
BUTTON
SAFETY
BEAM
LIMIT
SET
OPEN
FORCE
CLOSE
FORCE
RADIO
SIGNAL
LEARN
CODE
COM
DO NOT
PUSH
LIMIT SET
UNLESS
DOOR IS
ATTACHED
NOTE:
USE ONLY WITH
SERIES II CONTROLS
CLOSE
MORE
OPEN
MORE
CLOSE OPEN
LIMIT ADJUSTMENT
U.S. Patent No. 5,243,784
5,221,869
MORE MORE
LIMIT ADJUSTMENT
CLOSE
OPEN
PUSH
LIMITS
TO SET
4
3
2
1
CLASS 2
NEC
STEALTH
PRO-MAX
Fig. 9-1
24
8
...
FINE LIMIT SWITCH ADJUSTMENT
FOR HELP-1.800.354.3643 OR GENIECOMPANY.COM
MORE MORE
LIMIT ADJUSTMENT
CLOSE
OPEN
PUSH
LIMITS
TO SET
4
3
2
1
CLASS 2
NEC
LIMIT ADJUSTMENT
CLOSE
MORE
OPEN
MORE
Fig. 8-1
9
...
REMOTE CONTROLS
* Remotes vary depending on model. Your operator will
have one or the other.
(continued on next page)