GE Monogram 2900 Series Air Conditioner User Manual


 
3
ge.com
Electric Heat Amps include electric heater and fan motor current draw.
265-volt units are to be permanently connected in compliance with National Electrical Code and local codes and have a factory-installed junction box on the chassis.
Each 265-volt sub-base kit consists of sub-base with appropriate receptacle for minimum circuit amperage, chaseway to route power connector from sub-base to chassis
and wiring to connect sub-base to building wiring.
265-Volt Power Connection Kit must be ordered separately.
Power Connection Kits
Zoneline
®
Chassis Nomenclature
The Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and
optional features included on the unit. When specifying or ordering the Zoneline chassis, the use of this nomenclature will
assure receiving the correct unit.
230/208-Volt Line Cord Connection Units
Line Cord
Kit
Electric
Heat
BTUH
Electric
Heater
Watts
Electric
Heat
Amps
Min. Circuit
Protection
(Amps)
RAK3153 8600/7100 2550/2090 11.6/10.6 15
RAK3203
11700/9600 3450/2820 15.5/14.1 20
RAK3303 17100/13900
5000/4090 22.3/20.3 30
Electric Heat Amps include electric heater and fan motor current draw.
Each Line Cord Kit has an integral Leakage Current Detection and Interruption (LCDI) or Arc Fault
Current Interrupter (AFCI) device as required by National Electrical Code (NEC) and Underwriters
Laboratories (UL) for units manufactured after August 1, 2004.
230/208-Volt Sub-Base and Direct Connected Units
Sub-Base
Direct
Connection
Kit
Electric
Heat
BTUH
Electric
Heater
Watts
Electric
Heat
Amps
Min. Circuit
Protection
(Amps)
RAK204D15P RAK4157 8600/7100 2550/2090 11.6/10.6 15
RAK204D20P RAK4207 11700/9600 3450/2820 15.5/14.1 20
RAK204D30P RAK4307 170100/13900
5000/4090 22.3/20.3 30
Electric Heat Amps include electric heater and fan motor current draw.
Units connected through sub-base do not require a LCDI or AFCI device since they are not
considered to be line-cord connected. Each 230/208-volt sub-base kit consists of sub-base with
appropriate receptacle for minimum circuit amperage, chaseway to route power connector from
sub-base to chassis, wiring to connect sub-base to building wiring and a short line cord with 9-pin
connector to connect to chassis and plug into receptacle in sub-base.
Short sub-base line cord may not be used without sub-base.
Junction box for 230/208-volt chassis must be purchased separately.
RAK4002A for 2900 and 3900 series units RAK4002B for 5800 series units.
265-Volt Sub-Base and Direct Connected Units
Sub-Base
Power
Connection Kit
Direct
Connection Kit
Electric Heat
BTUH
Electric Heater
Watts
Electric Heat
Amps
Min. Circuit Protection
(Amps)
RAK204E15 RAK5172 RAK5157 8600 2550 9.6 15
RAK204E20 RAK5202 RAK5207 11700 3450 13.0 20
RAK204E30 RAK5302 RAK5307
17000 5000 18.9 30
Important
Essential Elements Ordering Overview
230/208-volt line cord connected units — order line cord kit
230/208-volt sub-base connected units — order sub-base and junction box
265-volt units — order sub-base and power connection kit
EXAMPLE
A Z 5 8 H 1 2 D A D
Chassis series
29= deluxe line cool/
electric heat
39=deluxe line heat pump
58= premium line
heat pump
Unit type
E= cooling with electric
resistance heat
H= heat pump with electric
resistance heat
Zoneline
packaged
terminal
chassis
Nominal cooling capacity
07=7,000 BTUH cooling
09=9,000 BTUH cooling
12=12,000 BTUH cooling
15=15,000 BTUH cooling
Special Features
B=base unit
C=corrosion treated
D= internal
condensate
removal (ICR)
system (heat
pump models
only) (not for
coastal areas)
P= Dry Air 25 (2800
Series only)
Voltage/Phase/
Frequency
D= 230/208-Volt,
single-phase, 60 Hz
E= 265-Volt, single-phase,
60 Hz
Universal
power connection