Window Requirements
■ These instructions are for a standard double-
hung window. You will need to modify them for
other types of windows.
■ The air conditioner can be installed without
the accordion panels if needed to fit in a narrow
window. See the window opening dimensions.
■ All supporting parts must be secured to firm
wood, masonry or metal.
■ The electrical outlet must be within reach of
the power cord.
1
Storm Window Requirements
A storm window frame will not allow the air
conditioner to tilt towards the outside and
will keep it from draining properly. To adjust
for this, attach a piece of wood to the stool.
WOOD PIECES
—
WIDTH: 2″
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place a
piece of wood on the stool to make it 1/2″ higher
than the top of the storm window frame.
Attach securely with nails or screws provided by
the installer.
2
1/2″ higher
than frame
Storm window
frame
Wood
Stool
17
1
⁄2″ min.
26″ to 39″
(With accordion panels)
22
1
⁄4″ min.
(Without accordion panels)
10,000 BTU models 12,000 BTU models
18
1
⁄4″ min.
30″ to 43″
(With accordion panels)
26
1
⁄4″ min.
(Without accordion panels)