Stovax VFC Radiant & Convector Fire Range Indoor Fireplace User Manual


 
Protective clothing is not required when handling these articles,
but we recommend you follow normal hygiene rules of not
smoking, eating or drinking in the work area and always wash your
hands before eating or drinking.
To ensure that the release of RCF fibres are kept to a minimum,
during installation and servicing a HEPA filtered vacuum is
recommended to remove any dust accumulated in and around the
appliance before and after working on it. When servicing the
appliance it is recommended that the replaced items are not
broken up, but are sealed within heavy duty polythene bags and
labelled as RCF waste.
RCF waste is classed as stable, non-reactive hazardous waste and
may be disposed of at a licensed landfill site.
Excessive exposure to these materials may cause temporary
irritation to eyes, skin and respiratory tract; wash hands thoroughly
after handling the material.
NOTE: CERAMIC PARTS ARE FRAGILE.
6.1 Position the flame baffle on the rear of the tray. See diagram
13 arrow B.
6.2 Position the front coal, make sure it sits flat onto the burner
skin. See diagram 13 arrow C.
6.3 Place the coals following the appropriate diagrams and
instructions
16” AND REDUCED DRAUGHT COAL LAYOUT
6.4 Curved fronts (Holyrood and Richmond) -place 5 large coals
onto the front coal moulding ensuing that they rest against
the front, place 2 small coals on to the front coal, 1 at each
end. See diagram 14.
13
10
11
12
INSTALLATION INSTRUCTIONS
INSTALLATION
13
14
AR0944
AR0303
AR0311
5.9 Connect the 8mm gas supply pipe to the fire. See diagram 10.
5.10 Check the gas connections to the fire are sound. Light the fire
and check all joints on the appliance.
5.11 Check the appliance working pressure is correct. See
databadge.
5.12 Fit the fire trim to the convector box. See diagram 11.
5.13 Fit the fret to the fire front using the two securing screws. See
diagram 12.
5.14 If the appliance is fitted with an alternative Gazco front
please refer to the separate leaflet supplied with the front.
6. ARRANGEMENT OF FUELBED
COMPONENTS
ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS
The fuel effect and side panels in this appliance are made from
Refractory Ceramic Fibre (RCF), a material which is commonly
used for this application.