Stovax P8700CFCHEC Stove User Manual


 
23
IGNITION FUNCTIONAL CHECK 1


(e.g. soot, etc.) which could short the spark, clean the area.

Is there a spark?
Consult User
Instructions and retry.
Check alignment of pilot
burner head, change the
ignition lead.
See Replacing Parts, section 2.
Check isolation tap and
gas meter, retry.
Correct and
retry.
Purge the gas pipes and retry.
GO TO THE NEXT
CHART IGNITION
FUNCTIONAL CHECK 2
SYSTEM OK
There is a blockage in the system, check the inlet test point,
the mag seating and valve. Check thermocouple leads for correct orientation,
condition and connection
Is the gas turned on to the
appliance?
Is the gas pressure correct?
Has the system got
any air in it?
Does the pilot light?
Is the control being
operated correctly?

with a match?
No Yes
No
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
Yes
SERVICING INSTRUCTIONS
SERVICING / FAULT FINDING CHARTS
1. SERVICING REQUIREMENTS
This appliance must be serviced at least once a year by a
competent person.
All tests must be serviced by best practice as described by the

1.1 Before any tests are undertaken on the stove:
 
there are no gas leaks prior to starting work.
  
Special checks
1.2.1 Clean any lint or fluff from the pilot - pay particular
attention to the aeration hole in the side of the pilot
1.2.2 Clean away any fluff or lint from under the burner
1.2.3 Check the spark gap on the pilot is correct


checks
1.3 Advise the customer of any remedial action taken.
REPLACE BATTERIES BEFORE ATTEMPTING TO RECTIFY ANY
FAULTS
IF THE FIRE DOES NOT WORK, BUT HAS WORKED IN THE
PAST:
CHECK THE EMERGENCY SHUT OFF SWITCH,
(BOTTOM RIGHT CORNER BY THE DOOR), IS
SWITCHED ON, SEE USER SECTION, PAGE 6
ELECTRONIC CONTROL VALVE FAULT ANALYSIS
Symptom Cause Remedy
3 short beeps from
control
Batteries low in
appliance
Replace appliance
batteries
No ignition, 5 seconds
continuous tone (there
can be several short
beeps before)
1. ON/OFF
switch is in OFF
position
2. Loose/dam-
aged wire
1. Move switch to
ON position
2 Check
interrupter block
and wires
No ignition, no tone,
motor turned slighted
when operated
Receiver board
damaged
Replace receiver
No pilot ame and
control continues to
spark
Thermocouple
circuit wired
incorrectly
Correct wiring
Pilot lights, control
continues to spark,
vale shuts down after
10-30 seconds
1. No spark at
pilot burner
2. Loose/dam-
aged wire
1. Rectify spark at
pilot burner
2. Check inter-
rupter and wires