Stovax P8700CFCHEC Stove User Manual


 
14
INSTALLATION INSTRUCTIONS
INSTALLATION
3
AR1963
3. STUD WORK INSTALLATION
THERE IS AN OPTIONAL DUCT KIT, CODE No. 8572
WHICH CAN BE FITTED AT THE SAME TIME AS THE
APPLIANCE INSTALLATION.
3.1 Combustible parts of the stud work must be kept beyond

framework is protected by non-combustible material, you
must maintain these dimensions, Diagram 4.
4
AR1953
3.1.1 Do not pack the void around or above the appliance with
insulation materials such as mineral wool.
3.1.2 Th E v O i d b u i l T f O r T h E cassETTE m u s T bE vE NT il aT Ed TO
prEvENT a b u i l d-u p O f h E a T . if T h E v O i d is sEalEd, T h E N y O u
m u s T fiT v E NT s a T b O T h l O W a N d h i g h lEvEls O f a pp rO xim aT El y
50c m
2
E ac h. ThEsE v E NT s m u s T Tak E c O l d ai r f r O m T h E r O O m
a N d rE Tur N W a r m ai r b ac k i N TO T h E r O O m .
3.1.3 aN a c cE ss h a T c h m u s T bE lEfT i N T h E s i d E O f T h E c h i m N E y
brEasT f O r f u T u rE sErviciNg a N d iNspEcTiON O f T h E f l u E a N d
ap pl ia Nc E.
3.2 STUD WORK INSTALLATION METHOD 1 (FRAME)
NOTE: With the legs fitted, this appliance can stand
directly on the floor (normally in a false chimney breast),
or without the legs on a protected platform at the
required height, Diagram 5
5
AR1964
Build the stud work chimney breast and enclosures to the
desired size to include the protected platform at the
required height.

non-combustible material as shown, Diagram 6
6
AR1902
 
 
 
void on the left-hand side
 
into the stud work at the correct height. This bar needs to
be recessed into the stud work, Diagram 5
It may be advisable at this stage to remove the fire before
plastering the enclosure.