14
INSTALLATION INSTRUCTIONS
COMMISSIONING
• Close all openable doors and windows in the room
• Ignite the stove and operate on maximum for 10 minutes
• Remove the plastic sight plug from the right hand side of
the stove
• Position a lighted smoke match just inside the draught
diverter opening
• Check all smoke is drawn into the opening by looking
through the sight hole, Diagram 1.
If there is any doubt, run the stove for a further 10
minutes, and repeat the test.
If there are any extractor fans in adjacent rooms, the test
must be repeated with the fans running on maximum and
interconnecting doors open.
IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE
AND SEEK EXPERT ADVICE.
For future reference record the installation details on the
commissioning sheet at the start of these instructions.
1
AR1493
1. COMMISSIONING