6. LIGHTING THE NEMOS
6.1 Locate the control valve on the appliance. There are two
control knobs on the valve, the right hand knob controls the
pilot ignition and the left hand knob controls the main
burner.
6.2 If your appliance has already been upgraded to battery
remote control, please refer to the instructions provided
with the upgrade to operate the remote control. The
following instructions will work for either situation.
6.3 Ensure that the left hand control knob is pointing to off (
).
6.4
Ensure that the right hand control knob is pointing to off
( ).
6.5 Press in the right hand control knob and rotate it anti-
clockwise until a click is heard (keep pressing in) and the
knob is pointing to pilot (
). The pilot should now light. If
the pilot has not lit, repeat the procedure until it does.
6.6 Keep the control knob pressed for 10 seconds and then
release it, the pilot should stay alight. If the pilot goes out,
repeat the procedures until it does.
6.7 If the pilot will not light after repeated attempts, contact the
retailer or installer from whom the appliance was
purchased.
6.8 Turn the right hand control to point to main burner (
).
The appliance can now be controlled using the left
hand control knob.
6.9 Turn the left hand control knob to point to low fire (
),
the main burner will light on low. The burner can now
be controlled between low and high settings. Turn the
control knob anticlockwise to increase the flame height and
clockwise to decrease the flame height.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS
GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES.
7. COMMISSIONING
7.1 Check all ceramics, door etc.
7.2 Check flame picture.
7.3 Check gas pressure.
INSTALLATION INSTRUCTIONS