2.1 TOP FLUE UP & OUT KIT (8534/8534AN)
Vertical from the top of the appliance then horizontally out.
(See diagram 1A). The basic kit comprises:
1 x 200mm vertical length
1 x 500mm terminal length (cut to length on site)
1 x 90 degree elbow
1 x wall plate
1 x 70mm restrictor
1 x 60mm restrictor fixing screws
The kit may be used on its own. (Note – with a 200mm rise
only the 500mm terminal length can be used). Extra lengths
may be added to the vertical and horizontal from the list
below.
2.2 TOP FLUE UP & OUT WITH ADDITIONAL
BEND
Any additional bend may be used on the horizontal section
(either 45° or 90°), but the overall horizontal flue run will be
reduced. Refer to diagram 1B.
2. FLUE OPTIONS
1A
AR1671
Start of bend to centre line of horizontal flue 170mm. Centre line
of vertical flue to end of bend 220mm.
1B
AR1672