4 2.1 L Hydraulic Pump Installation Instructions

The 2.1 L pump can be connected to the hydraulic system using one of two methods. The ve-connector method (page 8) uses the C1
and
C2
ttings to connect the pump to the cylinder and the H1
and H2
ttings to connect the pump to the helm. The three-connector method
(pages 5–7) uses only the H1 and H2 ttings, with a t-connector splitting the connection between the helm and cylinder. The return line tting
is
used in both cases to connect to only the helm. The check valves
do not need to be recongured if the boat is equipped with a balanced cylinder.
If the boat is equipped with an unbalanced cylinder, the check valves must be recongured (page 3). The bypass valve
is only opened for