Friedrich SQ10 Air Conditioner User Manual


 
21
AirÁ ow Selection and Adjustment
Air Á ow direction adjustment
The airÀ ow path may be adjusted to distribute air independently from the
left or right side of the discharge opening. Each of the banks of louvers
can be directed left, right, up or down in order to achieve the most optimum
airÀ ow positioning.
To adjust airÀ ow direction grab the lever in the center of the louver bank and
move it in the direction that you would like the air to be directed. Please
note that it is normal
that airÀ ow may be stronger out of one side of the
louvers than the other.
FRR083
LEFT AIRFLOW
LEVER
RIGHT AIRFLOW
LEVER
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner’s
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong oulet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
READ THIS FIRST! Electrical Requirements
Figure 12
Installation Instructions
IMPORTANT: Before you begin the actual installation of the air conditioner,
be sure your electrical requirements are as described below. Consult an
electrical professional as necessary to insure home wiring is per local
electrical codes.
CIRCUIT PROTECTION – An overloaded circuit will invariably cause
malfunction or failure of an air conditioner, therefore, it is necessary that the
electrical protection is
adequate. Due to momentary high current demand
when your air conditioner is started, use a "TIME DELAY" fuse or a HACR
type circuit breaker. Consult your dealer or power company if in doubt.
Your air conditioner must be connected to a power supply with the same
A.C. voltage and hertz as marked on the unit nameplate. Only alternating
current (A.C.), no direct current (D.C.), can be used.
The power cord has a plug with a grounding prong of approved type and a
ma
tching plug receptacle with ground is required. Refer to page 6 for the
correct type of plug receptacle for your model.