3) Electrical Information
Electrical Data
* Single circuit from main box. Based on copper wire, single insulated conductor at 60°C.
NOTE: Use copper conductors ONLY. Wire sizes are per NEC. Check local codes for overseas applications.
SAMPLE
VHA/VEA24K25
VHA/VEA24K34
VHA/VEA24K50
VHA/VEA24K75
VHA/VEA24K10
230/208 230/208 230/208 230/208 230/208 230/208
68 68 68 68 68 68
13.7/12.4 13.7/12.4 13.7/12.4 13.7/12.4 13.7/12.4 13.7/12.4
17.2/15.9 22.1/20.3 30.7/28.1 44.3/40.3 57.9/52.7 15.6/15.6
25/25 25/25 35/30 45/45 60/60 20/20
HARD WIRED
14/14 12/12 8/10 6/6 4/6 14/14
Voltage ( V)
LRA - Comp. (A)
Cooling Current (A)
MIN. Ckt. Amps (A)
Max Branch Circuit Fust (Amps)
Power Connection
Recommended Branch
Circuit Wire Sizes*
AWG - American Wire Gauge
MODEL
VHA/VEA24K00
Sample Nameplate (see your chassis nameplate)