Franklin 5870206300 Water Pump User Manual


 
22
NOTES: (A) Operating temperature is speci ed at full output power when installed as
described in Controller Location Selection on Page 11.
(B) Refer to Page 23 for detailed mounting dimensions.
(C) If a pump other than the default rating is used, refer to Page 8 for
drive con guration.
Input from
Power Source
(single-phase)
Voltage 190-260 VAC
Frequency 50/60 Hz
Current (max) 36 Amps (RMS)
Power Factor 1.0 (constant)
Power (idle) 65 Watts
Power (max) 7200 Watts
Output to Motor
(three-phase)
Voltage Adjusts with Frequency
Frequency Range
30-80 Hz (3 Hp pump)
30-60 Hz (5 Hp pump)
Current (max) 17.8 Amps (RMS, each phase)
Pressure Setting
Factory preset 50 psi
Adjustment range 25-80 psi
Operating
(A)
Conditions
NEMA 4 (indoor/outdoor)
Model 5870206300
Temperature (at 230 VAC
input)
-13 to 125°F
(-25 to 51°C)
Relative Humidity
0-100%, non-condensing or
condensing
Controller Size
(B)
(approximate)
Outer dimensions 14¾” H × 15¾” W × 8¾” D
Weight 34 lbs (15.5kg)
For Use With
(C)
Pump (60Hz)
3.0 Hp (default)
5.0 Hp
Motor (3-phase) 234317- series (5.0 Hp)
Specifi cations