WARNING
!
Serious or fatal electrical shock may result from failure
to connect the ground terminal to the motor, SubDrive
controller, metal plumbing, or other metal near the motor
or cable, using wire no smaller than motor cable wires. To
minimize risk of electrical shock, disconnect power before
working on or around the SubDrive300 system.
CAPACITORS INSIDE THE SUBDRIVE300 CONTROL-
LER CAN STILL HOLD LETHAL VOLTAGE EVEN AFTER
POWER HAS BEEN DISCONNECTED.
ALLOW 5 MINUTES FOR DANGEROUS INTERNAL
VOLTAGE TO DISCHARGE BEFORE REMOVING
SUBDRIVE300 COVER.
Do not use motor in swimming areas.
Before Getting Started
ATTENTION
!
This equipment should be installed by technically quali ed
personnel. Failure to install it in compliance with national
and local electrical codes and within Franklin Electric
recommendations may result in electrical shock or re
hazard, unsatisfactory performance, or equipment failure.
Installation information is available through pump
manufacturers and distributors, or directly from Franklin
Electric at our toll-free number 1-800-348-2420.
CAUTION
!
Use SubDrive300 only with Franklin Electric 4-inch
submersible motors as speci ed in this manual (see Table
1). Use of this unit with any other Franklin Electric motor or
with motors from other manufacturers may result in dam-
age to both motor and electronics.