www.fmiproducts.com
108796-01UT 13
P
I
L
O
T
ON
OFF
IN OUT
Figure 19 - Connecting Flexible Gas Line to Millivolt Valve
Gas Shutoff
Valve
Flexible Gas Line
Do NOT Kink
1/2" NPT
Incoming
Gas Line
Note:
1) Wire Connections
Not Shown for Clarity
2) * 1/8" NPT Plugged
Tapping
Red Surface Indicates For
Propane/LP Use Only
Pilot Adj
Inlet Pressure Tap
Outlet
Pressure Tap
CAUTION:Compoundsused
onthreadedjointsofgaspiping
shallberesistanttotheaction
of Liqueed Petroleum (LP or
propane)andshouldbeapplied
lightlytoensureexcesssealant
does not enter the gas line.
WARNING: All gas piping
andconnectionsmustbetested
forleaksaftertheinstallationis
completed.
After ensuring that gas valve
ison,applyacommercialleak
detection solution to all con-
nectionsandjoints.Ifbubbles
appear, leakscan be detected
and corrected.
Donotuseanopenameforleak
testing and do not operate any
applianceifaleakisdetected.
INSTALLATION
Continued
Complete your gas installation by connect-
ing incoming gas line with exible gas line.
Secure tightly with wrench but DO NOT
OVERTIGHTEN.
EMBER AND PAN MATERIAL
PLACEMENT
1. Open bag(s) of vermiculite and ll entire
burner pan until burner tube is completely
covered (see Figure 20).
2. Smooth pan material just even with edges
of burner pan.
3. Remove ember material from bag and
atten small amounts into quarter size
pieces and lay on top of surface of pan
material (see Figure 21).
4. Place just enough to cover entire surface
and leave about a 1/2" gap under lower
grate members to allow air to ow (see
Figure 22, page 14).
Figure 20 - Fill Entire Burner Pan with
Vermiculite
Figure 21 - Ember Material on Surface of
Pan Material (Vermiculite)
Vermiculite
(Pan Material)
Burner Pan
Grate
Ember
Material
Burner
Pan
Vermiculite (Pan Material)
Grate