FMI CDCFPRB Indoor Fireplace User Manual


 
www.fmiproducts.com
124979-01C4
PRODUCT IDENTIFICATION
Ignitor Button
Screen
Fireplace
Cabinet
Log
Control
Knob
Figure 1 - Vent-Free Compact Dual Flame
Fireplace
Hood
Fireplace Cabinet
Logs
Ignitor
Button
Remote Control
(Optional)
Control Knob
Hood
OPTIONAL REMOTE CONTROL ACCESSORIES
SAFETY
Continued
5. Do not use this replace as a wood-burn-
ing replace. Use only the logs provided
with the replace.
6.
Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using
these added items can cause sooting. Do not
add lava rock around base. Rock and debris
could fall into the control area of replace.
7. This replace is designed to be smokeless.
If logs ever appear to smoke, turn off re-
place and call a qualied service person.
Note: During initial operation, slight smok-
ing could occur due to log curing and re-
place burning manufacturing residues.
8. To prevent the creation of soot, follow the
instructions in Cleaning and Maintenance,
page 20.
9.
Before using furniture polish, wax, carpet
cleaner or similar products, turn replace
off. If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
10. This replace needs fresh air ventilation to
run properly. This replace has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the re-
place if not enough fresh air is available.
See Air for Combustion and Ventilation,
page 6. If replace keeps shutting off, see
Troubleshooting, page 21.
11. Do not run replace
• where ammable liquids or vapors are
used or stored.
• under dusty conditions.
12. Do not use this replace to cook food or
burn paper or other objects.
13. Never place any objects in the replace
or on logs.
14. Do not use replace if any part has been
under water. Immediately call a qualied
service technician to inspect the room
replace and to replace any part of the
control system and any gas control which
has been under water.
15.
Turn off and unplug replace and let cool
before servicing. Only a qualied service
person should service and repair replace.
16. Operating replace above elevations of
4,500 feet could cause pilot outage.
17. Do not operate replace if log is broken.
Do not operate replace if log is chipped
(dime-sized or larger).
18. To prevent performance problems, do
not use propane/LP fuel tank of less than
100 lb. capacity.
19. Provide adequate clearances around air
openings.
There is are two optional remote control that
can be purchased separately for Remote-
Ready Models:
wall switch
hand-held ON/OFF remote
wall thermostat
hand-held thermostat remote
See Accessories, page 31.