Fig. 2.13
R
1
Regulation screw (Semirapid burner)
R
2
Regulation screw (Inner crown of dual burner)
R
3
Regulation screw (Outer crown of dual burner)
R
1
R
3
R
2
SETTING THE BURNER MINIMUM OF THE COOKTOP BURNERS
When switching from one type of gas to another, the minimum fl ow rate must also be cor-
rect: the fl ame should not go out even when passing suddenly from maximum to minimum
fl ame.
To regulate the fl ame (fi g. 2.13) follow the instructions below:
Semirapid burner
• Light the burner.
• Set the gas valve to
position (minimum rate).
• Remove the knob.
• With a thin screwdriver, turn the regulation screw “R
1
” until adjustment is correct.
Inside crown of DUAL burner
• Light the DUAL burner.
• Set the gas valve to
position (minimum rate of inner crown).
• Remove the knob
• With a thin screwdriver, turn the regulation screw “R
2
” until adjustment is correct.
Outside crown of DUAL burner
• Light the DUAL burner.
• Set the gas valve to
position (minimum rate of inner and outer crowns).
• Remove the knob.
• With a thin screwdriver, turn the regulation screw “R
3
” until adjustment is correct.
For LP/PROPANE gas, tighten the adjustment screws completely.
2