CONVERSION TO LP/PROPANE GAS (OR CONVERSION BACK TO THE
ORIGINAL GAS - NATURAL GAS)
Every range is provided with a set of ori ces for the various types of gas.
Select the ori ces to be replaced according to the “ORIFICES TABLE”.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each ori ce.
CAUTION: Save the ori ces removed from the appliance for future use.
SETTING THE PRESSURE REGULATOR
The pressure regulator is accessible by removing the storage drawer; the pressure regulator is positioned
on the rear right side of the range ( g. 2.9).
To remove the storage drawer:
1. Open the drawer completely ( g. 2.6)
2. Move down the lever of left guide ( g. 2.7) and up the lever of right guide ( g. 2.8).
3. Remove the drawer holding the levers in the same position ( g. 2.6).
Fig. 2.7
Fig. 2.6
Fig. 2.8