Table A-1 Beckett AF Oil Burner Set-Up
Beckett AF Series Oil Burners
(For use with chimney vented units only)
Furnace
Model
Output
BTU/Hr
Burner
Model
Nozzle
Pump
Pressure
Flow Rate Head
1
Static
Plate
WML-60C
2
58,000 AF76BNHS 0.50 / 80°A 100 PSIG 0.50 USGPH F3 3- in.
WML-80C 75,000 AF76BNHS 0.65 / 80°A 100 PSIG 0.65 USGPH F3 3- in.
WML-90C 85,600 AF76BNHS 0.75 / 80°A 100 PSIG 0.75 USGPH F3 3- in.
MPL-90B 85,500 AF76XN 0.75 / 80°A 100 PSIG 0.75 USGPH F3 2- ¾ in.
MPL-100B 96,000 AF76XN 0.85 / 80°A 100 PSIG 0.85 USGPH F3 2- ¾ in.
MPL-120B 112,000 AF76XN 1.00 / 60°A 100 PSIG 1.00 USGPH F3 2- ¾ in.
MPL-130B 123,000 AF76YB 1.10 / 70°A 100 PSIG 1.10 USGPH F6 2- ¾ in.
1
Head is shielded by ceramic insulator.
2
Low Firing Rate Baffle required when using a 0.50-gallon nozzle.
Table A-2 Beckett AFII Oil Burner Set-Up
Beckett AFII Series Oil Burners
(For use with sidewall vented units using outdoor combustion air)
Furnace
Model
Output
BTU/Hr
Burner
Model
Nozzle
Pump
Pressure
Flow Rate Head
WML-60CB2 63,500 AFII-85 0.50 / 60°A 145 PSIG 0.55 USGPH FB0
WML-80CB2 75,000 AFII-85 0.60 / 60°A 145 PSIG 0.65 USGPH FB3
WML-90CB2 85,600 AFII-85 0.70 / 60°A 145 PSIG 0.75 USGPH FB3
MPL-90BB2 85,500 AFII-150 0.70 / 60°A 145 PSIG 0.75 USGPH FB0
MPL-100BB2 96,000 AFII-150 0.80 / 60°A 145 PSIG 0.85 USGPH FB3
MPL-120BB2 112,000 AFII-150 0.85 / 70°A 145 PSIG 1.00 USGPH FB3
Table A-3 Riello 40F Series Oil Burner Set-Up
Riello 40F Series Oil Burners
(For use with chimney vented units)
Furnace
Model
Output
BTU/Hr
Burner
Model
Nozzle
Pump
Pressure
Flow Rate Air Gate
Turbulator
Setting
WML-60CRF 59,500 40F3 0.50 / 60°W 105 PSIG 0.51 USGPH 2.6 1.0
WML-80CRF 75,000 40F3 0.60 / 60°W 115 PSIG 0.65 USGPH 2.6 1.5
WML-90CRF 85,600 40F3 0.65 / 60°W 135 PSIG 0.75 USGPH 3.6 2.0
MPL-90BRF 85,500 40F5 0.60 / 60°W 145 PSIG 0.75 USGPH 2.25 0.0
MPL-100BRF 96,000 40F5 0.65 / 60°W 145 PSIG 0.85 USGPH 2.5 0.5
MPL-120BRF 112,000 40F5 0.85 / 60°W 145 PSIG 1.00 USGPH 2.75 1.0