Faber MISTY Indoor Fireplace User Manual


 
UK/IRL
2
UK/IRL
3
1. INTRODUCTION
Note: these instructions should be read carefully and retained for
future reference.
Please leave these instructions with the user.
This guide is concerning the following types of appliances:
Widescreen interior: Types Silence and Feeling
Roundscreen interior: Type Misty
MV100 interior: Type Whisper
MV110 interior: Types Spectra Nova and Cadra Nova
Special features:
- Realistic flame and glow effect because of the "Log burner"
technology.
- Room sealed appliance, inlet and outlet are led to the outside
using a natural draught concentric pipe system (100 mm/150 mm)
(no power fan required). No additional ventilation required.
- Air supply and flue-gases go to outside atmosphere through wall or
roof. A maximum horizontal extension of 6 meters is possible.
- Remote Control option on all appliances.
- Meets the essential requirements of the European Gas Appliance
Directive (GAD) and carries the CE mark.
2. SAFETY AND GENERAL
INFORMATION
Before installation, ensure that the local distribution conditions
(identification of the type of gas and pressure) and the adjustment of
the appliance are compatible.
This gas appliance is factory set and shall not be adjusted by the
installer.
This appliance does not contain any component manufactured from
asbestos or any asbestos related products.
The pilot and flame sensing device fitted to this fire is also a safety
device. If for any reason any part of the pilot assembly is to be
replaced the entire assembly including the pilot burner, thermocouple,
electrode and injector must be exchanged complete for a pilot assembly
from the original manufacturer only.
Ventilation
This appliance is room-sealed and doesn't require purpose provided
ventilation.
2.1 General safety
It is the law in the UK that all gas appliances, are installed by a
competent person in accordance with the Gas Safety (Installation and
Use) Regulations (as amended), the relevant British Standards for
Installation work, Building Regulations, Codes of Practice and the
manufacturers instructions.
The installation should also be carried out in accordance with the
following where relevant:
BS5871 Part1 BS5440 Parts 1 & 2 BS1251.
Building Regulations Document J (as applicable).