EverFocus EDSR 400F Boiler User Manual


 
EVERFOCUS ELECTRONICS CORPORATION
¾ RS232 Parity: This field is to select the parity level at which you will be
connected. You can choose between None, Odd, or Even parity levels.
Default is set to none. To change this, simply use the Jog Dial on the DVR.
Press the Enter key to make your selection.
¾ RS232 Data Bit: This field is the data bit at which you will be transferring.
There are two settings for this option: 8 or 7. The default is set to 8. To
change this, simply use the Jog Dial on the DVR. Press the Enter key to
make your selection.
RS485:
¾ RS485 Baud Rate: This field is to set the speed at which is used to transmit
instruction or information through the RS485 port on the DVR. There are
six different speeds, 1200 BPS, 2400 BPS, 4800 BPS, 9600 BPS, 19200 BPS,
and 3840 BPS. The default setting from the factory is 9600 BPS. To change
this, simply use the Jog Dial on the DVR. Press the Enter key to make your
selection.
¾ RS485 Stop Bit: This field is to set the stop bit for the RS485 connection.
There are two different stop bits, 1 or 2. The default in the DVR is set to 1.
To change this, simply use the Jog Dial on the DVR. Press the Enter key to
make your selection.
¾ RS485 Parity: This field is to select the parity level at which you will be
connected. You can choose between None, Odd, or Even parity levels.
Default is set to none. To change this, simply use the Jog Dial on the DVR.
Press the Enter key to make your selection.
¾ RS485 Data Bit: This field is the data bit at which you will be transferring.
There are two settings for this option: 8 or 7. The default is set to 8. To
change this, simply use the Jog Dial on the DVR. Press the Enter key to
make your selection.
¾ RS232/RS485 ID: This entry is used to assign each device its own ID code
if more than one unit is used through the RS232/RS485 connection. The
ID codes are available for the DVR: from 001 to 200. The default is set to
001. To change this, simply use the Jog Dial on the DVR. Press the Enter
key to make your selection.
¾ Please Note: Settings for remote keyboards :
RS-485 baud rate: 9600, Stop bit: 1, Parity: none, ID range: 1~200.
31