Enviro Sonnet Stove User Manual


 
Initial Installation
QUALIFIED INSTALLERS ONLY
ELECTRICAL REQUIREMENTS:
The fan will not operate if the appliance is cold. A few minutes after the appliance is lit and the fan is set
to low or high, the fan will automatically turn on. The fan will automatically turn off after the appliance
has cooled down.
Fan Control
Black
White
Grey
Green
Black
Power Cord
120V AC
FAN
120
o
F (49
o
C)
Temperature Sensor
CNT1
CNT4
CNT2
CNT3
Low High
Grey
CNT5
Black
CNT6 CNT8
CNT7
CNT9
The replace must be electrically connected and
grounded in accordance with local codes or, in the
absence of local codes, with the current CSA C22.1
Canadian Electrical Code Part 1, Safety Standards
For Electrical Installations, or The National Electrical
Code ANSI / NFPA 70 in the US.
WARNING: The electrical grounding instructions
must be followed. The fan kit is equipped with a
three-prong (grounding) plug for your protection
against shock hazard, and should be plugged
directly into a properly grounded three-prong
outlet. DO NOT cut or remove the grounding prong
from this plug.
CAUTION: When servicing controls, label all wires
prior to disconnection. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
Figure 46: Wiring of a valve.
Figure 45: Fan wiring diagram.
OPTIONAL FAN KIT:
Tools Required:
● ” Socket or Driver or Flat Head Screwdriver ● Pliers ● T-20 Screwdriver ● Utility Knife
24