Enviro 50-1628 Stove User Manual


 
Operating Instructions
For Your Safety, Read Safety Precautions
And Lighting Instructions Before Operating
8
The ideal ame will be blue at the base and light orange above. The ames should be of medium height.
If the ames look like this (refer to Figure Figure 43 or Front Cover), no adjustment is needed. If the
ames are fairly short and mostly blue, the replace is getting too much air. Therefore, the air shutter
should be closed slightly until the correct ames are achieved. Flames that are very orange, with tall,
dark, stringy tips, are not getting enough air. Open the air shutter until the ames clean up. If the shutter
is opened, or closed all the way, and the correct ames cannot be attained, turn off the gas and contact
the dealer.
Warning: Incorrect air shutter adjustment may lead to improper combustion, which is a safety hazard.
Contact the dealer if there is any concern about the venturi adjustment.
Table 1: Air Shutter Setting Information.
Natural Gas Propane
Amount Air Shutter is Open ” (6mm) minimum Completely Open
REMOTE CONTROLS (OPTIONAL):
This replace can use an optional remote control or an optional cordless wall thermostat. If either of
these are to be used to control the replace for the majority of the time, leave the ON/OFF switch (on the
rear of the unit) in the “ON” position. Consult the instructions included with the remote/wall thermostat
for operation guidelines.
BLOWER SPEED (OPTIONAL):
The blower will come on only when the replace is up to temperature (approximately 12 minutes with
unit on high). When installed, the blower is equipped with a variable fan controller, located in the front
control panel. This control will adjust the fan speed from high to low or turn the fan off.
NORMAL SOUNDS DURING OPERATION:
Table 2: Normal Sounds
Component Sound & Reason
Cara Creaking when heating up or cooling down.
Burner Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor Clinking when it senses to turn the blower on or off.
Pilot Flame Quiet whisper while the pilot ame in on.
Blower / Fan Air movement that increase and decreases with the speed of the blower.
The blower is pushing the heat from the replace into the room.
Gas Control Valve Dull click when turning on or off, this is the valve opening and closing.