England's Stove Works 55-TRP20 Stove User Manual


 
DAILY OPERATION
Refueling the Unit
Always press the “OFF” touch pad before refueling. This stove has a (approximately) 50-lb.
hopper, and should be refilled when the hopper level drops to three or four inches.
Note: The hopper lid will be warm; therefore, you should always use some type of hand protection.
NEVER place your hand near the auger while the stove is operating.
Note: Always ensure that all pellet matter is cleared from the hopper lid gasket before closing. Be
sure to close hopper securely before re-firing. Do not operate this unit with the hopper lid
open or unsecured.
Power Outage
If the power to the unit is interrupted for approximately three minutes or less, the unit will resume
operation when power is restored according to the following table:
Unit’s State Before Power Loss State When Power Returns
ON Start-Up
Start-Up Start-Up
Shut-Down Shut-Down
OFF OFF
If the power is interrupted for more than (approximately) three minutes, the unit will be “OFF”
when power returns.
Important: Do NOT open the hopper lid or the door to the unit during power outage. Open
the closest outside door and a window to eliminate the home’s natural draft.
Wait for power to be restored and then press the “ON” button to re-start the unit, if necessary.
We highly recommend the use of a surge protector with your unit, as power surges and failures can
affect the operation of any electrical appliance.
We do not recommend leaving home with the stove on the higher heat ranges; it is recommended
that the stove be left on the lower heat ranges (Heat Range setting 1 or 2).
NOTE: Remember: 1) It is very important for the unit to be vented properly (see instructions on
Outside Air), as the natural draft is needed to clear the smoke from the stove.
2) Do not open the hopper lid (or the unit’s door). This may cause fire to burn
in the hopper.
Fuel Outage
If the unit should run out of pellets, simply reload the hopper and press the “ON” button (only
once) to re-start the unit. If the unit runs without pellets, after one hour the unit will shut down.
NOTE: Even if flames are visible inside the fire box always
press the “ON” button to ensure that
your unit will restart.
Combustion Blower Failure
If the Combustion (exhaust) Blower should fail on this unit, a Vacuum Shut-Down Switch will
automatically stop the stove. This will shut your unit completely off, and there will be an “E-1” code in
the Heat Range and Blower Speed windows on the Control Board.
Do not open the hopper lid or door.
At this point you will need to contact Technical Support at (800) 245-6489.
NOTE: It is very important for the unit to be vented properly (see instructions on Outside Air), as the
natural draft is needed to clear the smoke from the stove.