England's Stove Works 25-PDV Stove User Manual


 
FLOOR AND WALL PROTECTION
Floor Protection
If your floor is constructed of a non-combustible material such as brick or concrete, there is
no need for floor protection. If the floor is constructed of a combustible material such as
hardwood, linoleum, or carpet, then you will be required to use floor protection between the unit
and the combustible. The protection should be U.L. approved or equal, and should be large
enough to provide a minimum of six inches (6”) behind and on both sides of the stove. The
clearance in front of the stove should be at least six inches (6”). This freestanding pellet unit will
need a minimum 36” x 36” floor protector.
Wall Protection
From the rear and the sides of this stove only six inches (6”) of clearance is required to
paneling, wallpaper or drywall. The pellet vent pipe would require the standard three inches (3”)
clearance, or as recommended by the manufacturer. Normally additional wall protection is not
required with this type unit.
1. If 3” flue pipe exceeds 15’ in length, increase to 4” flue pipe for remaining flue connections.
2. Total flue length should not exceed 35’.
3. Horizontal run not to exceed 4’.
4. Floor protector required: Min. size 36” x 36”.
5. If the total run of outside air connection exceeds 6’, if more than 2 elbows are used, or if a
basement install, use 3” metal pipe (and coupler) instead.
6. Outside Air is mandator
y
f
or
p
ro
p
er sa
f
e o
p
eration.
Must have minimum
3” adapter before tee
for longer run.
For shorter run (such
as Masonry
Connection below),
tee alone is acceptable.
Masonr
y
Connection
Illustration 1
Basement Installation should
be performed by professional
installer. Use 3” metal pipe
and coupler for Outside
Combustion Air. Minimum 3’
clearance from ground to the
Pellet Vent Exhaust Pipe.
Freestanding Pellet Installation
Caution: Follow the pipe manufacturer’s installation instructions and directions for
passin
g
throu
g
h combustible walls and ceilin
g
s. Check local codes in
y
our area.
Our Part AC-3000 is
acceptable for
through-the-wall
installation.
(AC-3100 for 4000+
ft. installations.)