Empire Comfort Systems VF24FP2-1 Indoor Fireplace User Manual


 
Page 2120248-2-0806
INSTALLING OPTIONAL BRICK LINER EHL-24-1.
1. Remove screen assembly from fireplace.
2. Remove logs from burner assembly.
3. Insert rear brick liner and (2) side brick liners onto bottom
of the inner casing. Align grout lines on rear brick liner with
grout lines on side brick liners. You must insert rear brick
liner before inserting the (2) side brick liners.
4. Loosen top and bottom 10 x 1/2" screws from each side of
firebox.
5. Place the (2) liner mounting brackets over the front edges of
the (2) side brick liners. Attach liner mounting brackets to
outer casing with (4) four 10 x 1/2" screws from Step 4.
6. Replace logs into burner assembly. Refer to "Log Placement,"
Page 12.
7. Attach screen assembly to fireplace.
8. Installation of optional brick liner is completed.
EHL-24-1 for Unvented Gas Fireplace
Model
VF24FP2-1, VF24FP3-1
PARTS LIST FOR EHL-24-1, BRICK LINER KIT
Part Number Description
11504
Liner Mounting Bracket - Front, 2 Required
R-5769 Brick Liner - Rear
R-5770 Brick Liner - Side Left
R-5771 Brick Liner - Side Right
OPTIONAL BRICK LINER INSTALLATION INSTRUCTIONS