Empire Comfort Systems DV-35-2SG Furnace User Manual


 
12434-3-0903
Page 5
INTRODUCTION
SPECIFICATIONS
Introduction
Always consult your local Building Department regarding
regulations, codes or ordinances which apply to the installation of
a direct vent wall furnace.
Instructions to Installer
1. Installer must leave instruction manual with owner after
installation.
2. Installer must have owner fill out and mail warranty card
supplied with furnace.
3. Installer should show owner how to start and operate
furnace and thermostat.
Warning:
Any change to this furnace or its control can be
dangerous. This is a heating appliance and any panel,
door or guard removed for servicing an appliance
must be replaced prior to operating the appliance.
General Information
This furnace is design certified in accordance with American
National Standard/CSA Standard Z21.86 and CSA 2.32 by the
Canadian Standard Association, as a Gravity Direct Vent Wall
Furnace to be installed on an outside wall according to these
instructions.
Any alteration of the original design, installed other than
as shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
Important
All correspondence should refer to complete Model No.,
Serial No. and type of gas.
Notice: During initial firing of this unit, its paint will bake out
and smoke will occur. To prevent triggering of smoke alarms,
ventilate the room in which the unit is installed.
Installation in Residential Garages
Gas utilization equipment in residential garages shall be
installed so that all burners and burner ignition devices are
located not less than 18" (457mm) above the floor.
Such equipment shall be located, or protected, so it is not subject
to physical damage by a moving vehicle.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization
equipment or accessories and repair and servicing of equipment
shall be performed only by a qualified agency. The term
"qualified agency" means any individual, firm, corporation or
company which either in person or through a representative is
engaged in and is responsible for (a) the installation or
replacement of gas piping or (b) the connection, installation,
repair or servicing of equipment, who is experienced in such
work, familiar with all precautions required and has complied
with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by a
licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
The installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code ANSI
Z223.1/NFPA 54* Natural Gas and Propane Installation
Code, CSA B149.1.
*Available from the American National Standards Institute, Inc., 11 West 42nd St.,
New York, NY 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), input ratings
should be reduced at the rate of 4 percent for each 1,000 (305m)
feet above sea level. Canadian High Altitudes for locations
having an elevation above mean sea level between 2,000 feet
(610m) and 4,500 feet (1370m), the manifold pressure is to be
decreased from 4.0" w.c. (.996kPa) to 3.2" w.c. (.796kPa) for
Natural Gas and from 10.0" w.c. (2.49kPa) to 8.0" w.c. (1.992kPa)
for Propane Gas.
Model DV-25 DV-35
Input BTU/HR (KW/H) 25,000 (7.3) 35,000 (10.3)
Height 27 3/4" (705mm) 27 3/4" (705mm)
Width 37" (940mm) 37" (940mm)
Depth 11 1/2" (292mm) 11 1/2" (292mm)
Gas Inlet (Pipe) 1/2" (13mm) 1/2" (13mm)
Accessories For Above Furnaces
Blower Package DRB-1 DRB-1
Vinyl Siding Vent Kit DV-822 DV-822