CAC ELECTRICAL SPECIFICATIONS
Model #
Fan Motor Elect Heat
Total
AMPS
Min
Volt
M.C.A.
HACR
BRKR
Volts/HZ/PH
RLA H.P. K.W. AMPS
Small Cabinet 09/12
CAC09/12 208/230/60/1 0.35 1/10 0.4 197 0.5 15
CAC09/12 208/230/60/1 0.35 1/10 1.5 6.52 6.9 197 8.6 15
Medium Cabinet 18/24
CAC18/24 208/230/60/1 0.55 1/8 0.6 197 0.7 15
CAC18/24 208/230/60/1 0.55 1/8 3 13.04 13.6 197 17.0 20
Large Cabinet 30/36
CAC30/36 208/230/60/1 0.5, 0.5 1/10, 1/10 1.0 197 1.2 15
CAC30/36 208/230/60/1 0.5, 0.5 1/10, 1/10 5 21.74 22.7 197 28.3 30
S1C
Side
Discharge
CAC CASSETTE SYSTEM MATCHES
CAC
CAC ELECTRICAL SPECIFICATIONS
NOTE: Due to EMI’s ongoing product development program, all designs and specifications
are subject to change without notice.
S2C
Side
Discharge
COOLING SYSTEMS WITH CASSETTE UNITS
Condenser Cassette Btuh SEER SHR EER
Ref.
S1CA9 CACA12 9,000 13.0 .79 11.7
R22
S1CA2 CACA12 12,000 13.0 .72 12.2
R22
S1CA8 CACA24 18,000 13.0 .76 12.3
R22
S1CA4 CACA24 23.000 13.0 .67 11.8
R22
S1CA3 CACA36 30,000 13.5 .82 12.5
R22
S1CA6 CACA36 36,000 13.0 .74 12.6
R22
COOLING
SYSTEMS WITH S2C SIDE DISCHARGE
Cassette Condenser Btuh SEER SHR EER
Ref.
CACA12 S2CA99 18,000 13.0 .81 11.7
R22
CACA12 S2CA22 23,000 13.0 .74 11.8
R22
CACA12 S2CA92 21,000 13.0 .77 11.8
R22