Emerson M22 Carbon Monoxide Alarm User Manual


 
44
MAN-0076 Rev 05 Millennium II
December 07, 2012
Net Safety Monitoring Inc
Appendix B: Resistance Table
1
Distance
(Feet)
AWG #20
0.5mm
2
AWG #18
0.8mm
2
AWG #16
1.0mm
2
AWG #14
2.0mm
2
100
1.02
0.64
0.40
0.25
200
2.03
1.28
0.80
0.51
300
3.05
1.92
1.20
0.76
400
4.06
2.55
1.61
1.01
500
5.08
3.20
2.01
1.26
600
6.09
3.83
2.41
1.52
700
7.11
4.47
2.81
1.77
800
8.12
5.11
3.21
2.02
900
9.14
5.75
3.61
2.27
1000
10.20
6.39
4.02
2.53
1250
12.70
7.99
5.03
3.16
1500
15.20
9.58
6.02
3.79
1750
17.80
11.20
7.03
4.42
2000
20.30
12.80
8.03
5.05
2250
22.80
14.40
9.03
5.68
2500
25.40
16.00
10.00
6.31
3000
30.50
19.20
12.00
7.58
3500
35.50
22.40
14.10
8.84
4000
40.60
25.50
16.10
10.00
4500
45.70
28.70
18.10
11.40
5000
50.10
32.00
20.10
12.60
5500
55.80
35.10
22.10
13.91
6000
61.00
38.30
24.10
15.20
6500
66.00
41.50
26.10
16.40
7000
71.10
44.70
28.10
17.70
7500
76.10
47.90
30.10
19.00
8000
81.20
51.10
23.10
20.20
9000
91.40
57.50
36.10
22.70
10000
102.00
63.90
40.20
25.30
1