Electrolux F4VA1 Sewing Machine User Manual


 
16 Troubleshooting
Table 7.4 - Troubleshooting
Problem Possible cause What the user should do
The machine does
not start
No power to machine Check there is electrical power in the facility
Check connection to power lines
Turn on the main power switch
The display is dim Brightness of the display set too
low
Increase brightness by pressing button + on the control panel
The collar clamp does
not close
The clamp is excluded Press the COLLAR exclusion button on the control panel to deselect (when the light
is off the clamp works)
Air pressure is inadequate or ab-
sent
Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)
The carriage does not
move
The parameter H06 is set to 03,
04 or 05
Change the setting of the parameter (see table 5.2)
Reflective material is worn out Replace reflective material strip
The photocell beam does not hit
the reflective material
Check that the photocell has not been moved. If necessary, redirect the photocell
beam on the reflective material and lock well the photocell position
The front clamp does
not move
Clamp is excluded Remove the exclusion by pressing the FRONT button on the control panel (when
the light is off the clamp is active)
Air pressure is inadequate or ab-
sent
Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)
The rear clamp does
not move
Clamp is excluded Remove the exclusion by pressing the REAR button on the control panel (when the
light is off the clamp is active)
Air pressure is inadequate or ab-
sent
Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)
Check and regulate clamps pressure. Minimum pressure is 3 bar
(Figure 4.3, knob 18 and gauge 17)
Both side clamps do
not move
Clamps are excluded (parameter
H05 set to 00)
Set parameter H05 to 01
Air pressure is inadequate or ab-
sent
Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)
Check and regulate clamps pressure. Minimum pressure is 3 bar
(Figure 4.3, knob 18 and gauge 17)
Both side expanders
do not move
Air pressure is inadequate or ab-
sent
Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)
Check and regulate clamps pressure. Minimum pressure is 3 bar
(Figure 4.3, knob 18 and gauge 17)
Both sleeve arms do
not move
The arms are excluded Press the ARMS exclusion button on the control panel to deselect (when the light
is off the arms work)
Air pressure is inadequate or ab-
sent
Check and regulate general pressure to 6 bar (Figure 4.3, knob and gauge on
filter 3)
No steam from ma-
chine
Steam feed valve closed Open steam feed valve
Steam time set at zero Set steam time greater than zero
No blowing Blowing time set at zero Set blowing time greater than zero
Inadequate ventila-
tion
Blowing adjustment set too low Shift the blowing adjustment lever (12 - Figure 4.3) towards the + mark
F4VA1-ed3605