Drolet DH04200 Stove User Manual


 
INSTALLATION INSTRUCTIONS
LOCATING THE STOVE
Install the stove as close to the chimney as possible.
Many configurations are possible, the most frequent are illustrated in figures 1, 2 and 3.
Respect clearances indicated on page 1. They have been tested according to approvals.
Always respect clearances of stove pipes manufacturers. Larger clearances always prevail.
Figure 1 : CORNER INSTALLATION
Figure 2 : PARALLEL INSTALLATION
Figure 3 : WALL INSTALLATION
Table 1 : CLEARANCES TO COMBUSTIBLES
mm in
Back 255 10
Side 255 10
Corner 255 10
Top 915 36
Flue Pipe 230 9
IMPORTANT: It is essential to ensure that the room where the stove is located is sufficiently
ventilated to provide an adequate air supply.
If your home is well insulated, it is possible that you will have to install an outside fresh air intake.
THE BURNING OF ONE LITRE OF FUEL (OIL) REQUIRES APPROXIMATELY 30 M
3
OF AIR AND
WILL PRODUCE ABOUT 0.8 KG OF WATER OF WATER VAPOR AND 9 M
3
OF CARBONE
DIOXIDE AND ATMOSPHERIC NITROGEN. A SOURCE OF AIR FROM THE OUTSIDE IS NEEDED
TO REPLACE COMBUSTION AIR.
Page 2 of 15