TABLE OF CONTENT
TECHNICAL DATA.........................................................................................................................................1
INSTALLATION INSTRUCTIONS ..................................................................................................................2
LOCATING THE STOVE ......................................................................................................................... 2
CHIMNEY INFORMATIONS.................................................................................................................... 3
CONNECTING THE STOVE TO THE CHIMNEY ................................................................................... 4
LEVELING THE UNIT.............................................................................................................................. 5
FIXATION OF STOVE TO FLOOR.......................................................................................................... 6
CONNECTING STOVE TO OIL TANK....................................................................................................6
AJUSTEMENT THE DRAUGHT.............................................................................................................. 7
OPERATION INSTRUCTIONS ....................................................................................................................... 8
COMBUSTIBLE ....................................................................................................................................... 8
LIGHTING PROCEDURES ..................................................................................................................... 8
CHANGING INTENSITY.......................................................................................................................... 9
TURNING THE STOVE OFF................................................................................................................... 9
CLEANING PROCEDURES.................................................................................................................... 9
TROUBLESHOOTING GUIDE .............................................................................................................. 10
TECHNICAL DATA
EVEREST OIL BURNING STOVE
COMBUSTIBLE : OIL N
O
1 OIL N
O
2
HEAT INPUT : Kw BTU/h Kw BTU/h
Minimum: 5,9 20 450 4,8 16 600
Maximum: 10,9 37 250 9,6 33 150
FLOWRATE : cc/min litres/h cc/min litres/h
Minimum: 9,9 0,60 7,5 0,45
maximun: 17,3 1,04 16,1 0,97
MINIMUM DRAUGHT REQUIRED : 0,06 INWC 0,06 INWC
EFFICIENCY : % %
with fan : 78,5 79
without fan : 77 77
CLEARANCES TO COMBUSTIBLES
Mm in
Back 255 10
Side 255 10
Corner 255 10
Top 915 36
A MINIMUM CLEARANCE OF 9’’ (230 mm)
FROM SINGLE WALL FLUE PIPE TO
COMBUSTIBLES MUST BE ALLOWED.
DIMENSIONS
mm in
Height : 990 39
Width : 520 20
Depth : 680 26 ¾
Ø outlet flue pipe : 130 5
Ø burner : 255 10
Glass ( 3 ) : 92 x 250 3
5/8
x 9
7/8
Weight : 93 kg 204 lbs
Page 1 of 15