Drolet 7000 MVRLC Indoor Fireplace User Manual


 
13. Install a 1/8” NPT plugged tapping for test gauge connection immediately
upstream of the gas supply connection to the appliance.
14. Install a shutoff valve to the gas line. Tighten securely using a pipe joint
compound.
15. Install a 3/8” flex connector to connect the shutoff valve to the gas valve on the
fireplace. Tighten securely using a pipe joint compound.
16. Check the gas line piping for leaks. Use a soap and water solution.
WARNING : DO NOT USE OPEN FLAME TO CHECK LEAKS.
17. If you decided to make a direct connection to the fan step 8, remove the power
cord and connect the 120 V line. To do so, unscrew the speed control unit and pull
away from the junction box a few inches. Unscrew the two mar connectors
attached to the cord (P) and the cord ground. Remove the cord and route the
supply line through the same holes. Make the electrical connection with the same
wires the cord was attached to. Screw the ground wire to the junction box (G).
If you prefer to use the six foot cord supplied, just connect it to a 120 V outlet.
18. If you want to turn the main burner ON and OFF using a wall switch :
8