INSTALLATION :
1. When the masonry fireplace that will receive the ULTRA FLAME gas insert is
thoroughly cold, remove all ashes and vacuum clean.
2. Remove the glass front from the gas insert following page 11 instructions.
3. Remove the burner and firebox bottom plate from the gas insert following page 12
instructions.
4. Remove the draft hood from the top of the appliance.
5. Move the ULTRA FLAME to the desired position and level the appliance using
the two bolts located in the back corners. Mark the location for the gas inlet pipe.
( We suggest using the hole in the back of the ULTRA FLAME for ease of
connection. )
6. Remove the ULTRA FLAME gas insert from the fireplace.
7. Route a 3/8” minimum NPT iron pipe gas line to the desired location.
8. If you wish to make a direct electrical connection to the blower without using the
six foot cord supplied, route a 120 volts, 60 Hz electrical power supply line to the
same location.
9. Remove or block open the masonry fireplace flue damper.
10. Install a certified 4” gas liner inside the chimney from its very top down to the
fireplace.
6