Drolet 7000 MVRLC Indoor Fireplace User Manual


 
OPERATING INSTRUCTIONS
LIGHTING INSTRUCTIONS :
1. Open the bottom louvers of the face plate to reach the control.
2. Turn the gas valve knob to the “OFF” position and wait 5 minutes.
Note : You have to depress the gas valve knob to turn from “PILOT” to “OFF” or from
“OFF” to “PILOT”.
3. Turn the gas valve knob to “PILOT”.
4. Depress and hold the knob while lighting the pilot by pressing the pilot igniter
button (RED button ). Keep the knob depressed for about 1 minute. Release the
knob. The pilot should continue to burn by itself, if not, repeat step 4.
Note : You may need to press the pilot igniter button more than one time to light the
pilot.
5. Turn the gas valve knob to the “ON” position.
6. Turn the face place mounted switch to the “ON” position. If you don’t have an
additional wall switch , the main burner will come on. Otherwise, turn the wall
switch to “ON” if you want the main burner to come on.
7. The other knob controls the gas flow and the power of the appliance.
SHUTDOWN INSTRUCTIONS
Main burner only : Turn off the face plate switch ( or wall switch ).
To relight the main burner, turn the switch on ( or the wall switch )
Pilot and Main burners : Turn the gas valve to the “OFF” position. Depress the knob to
pass from the “PILOT” to “OFF” position.
FAN OPERATION :
To turn the air blower “ON” or “OFF”, activate the face plate switch connected to the
yellow wires. The fan will not start if the appliance is cold. Operate the gas insert for at
least 15 minutes to heat up the thermo-switch. The fan will also turn itself off about 20
minutes after extinction of the main flame.
Note: The speed control must also be on to allow fan to work.