Dometic CWP 5311 Water System User Manual


 
Service and spare parts
Before calling service, use the trouble-shooting guide “If the water purifier stops working” to try to rectify the fault yourself. If service
is called in to solve a problem that is in this list, there is a risk that you will be responsible for the cost. The same applies if you have
used the appliance for a purpose other than that for which it is intended.
Note that electrical faults should always be rectified by a certified electrician.
Give the appliance’s product and serial numbers according to the data plate (see fig. A). The plate is located on the back of the water
purifier.
You can record these details here:
PROD.NO ............................................................
SER.NO ................................................................
Purchase date ........................................................
14
IF THE WATER PURIFIER STOPS WORKING
Data
Dimensions:
- height 340 mm
- depth 140 mm
- width 290 mm
Weight:
- on delivery 3.0 kg
- filled with water 3.7 kg
Capacity: 3.8 (±0.8) litres/minute 0.84 (±0.18) gpm (UK)
Inlet pressure: 0.3-5 bar (30-500 kPa) 5-72 PSI
Working temperature:
- ambient and water temperature 2 - 43 °C
Electrical data:
Connection 12-24 V DC
Low voltage protection 9 V
Resetting low voltage protection 10 V
Power consumption (excl. pump output):
- during purification 10 W
- during heating 12 W
- in standby 1 W
Fuse, slow blow 6.3 A
Pump current, max: 5 A
Requirements on feed water to water purifier
The tank must be filled with municipal water. In standing water (tank water) there is a risk of bacterial growth. The water purifier is
intended to purify the tank water.
Turbidity < 7.5 FNU
Chlorine 4 mg/litre
Organic content < 1 mg/litre
TECHNICAL DATA