ENGLISH18
HVAC SYSTEM POWERED BY INVERTER - SINGLE STARTING/HOUSE BATTERY BANK -
SHOREPOWER WITH CAB POWER OUTLETS
NOTES:
1) House batteries must be of the AGM dual
purpose deep cycle/starting type.
2) Alternator should be upgraded. Discuss
with Dometic Applications Department
for recommendation.
3) Inverter must be of approved type by Dometic
in order to insure proper operation of system.
4) Cable size should be chosen based on
voltage drop and load. Cable to inverter
should be 2/0 gauge or greater. All cables
should have an ampacity rating of greater
than the expected amp flow and/or the
overcurrent protection device.
Alternator
Battery 1
Battery 2
Battery 3
-
+
+
-
+
-
+
-
HVAC Unit
-
Battery 4
Battery 5
+
--
+
Battery 6
+
Overcurrent
Protection
120VAC Line
DC Wiring
AC Wiring
Shorepower Inlet
Y-Cord Splitter
to GFCI Receptacle
Cab Power
Outlet
Inverter with Shorepower
Pass-Thru Capability
OR Inverter/Charger
Battery-Powered Systems Installation Guidelines